Chapter 18
18-30
18.4.3 NUM
18.4.3.1 NUM List
0020-2022
T-18-39
18.4.4 NCU
18.4.4.1 NCU List
0020-2023
<TONE/ PULSE>
Operating Method
(1) Setting tone parameter
With "#NCU" displayed, press set key -> Press "#TONE/PULSE" set key
-> Pressing "#TONE" set key makes the setting mode for tone parameter.
(2) Setting pulse parameter
With "#NCU" displayed, press set key -> Press "#TONE/PULSE" set key.
-> Pressing "#PULSE" set key makes the setting mode for pulse parameter.
T-18-40
<DIAL TONE>
(1) Bit switch
Numeric parameter setting mode
Number
Parameter
Available setting range
02
RTN delivery condition X
1 to 99%
03
RTN delivery condition n
2 to 99 times
04
RTN delivery condition m
1 to 99 lines
05
NCC pause time (before ID code)
1 to 60 s
06
NCC pause time (after ID code)
1 to 60 s
10
T.30 T0 timer
Generally 55s
11
T.30 T1 timer (for receiving)
0 to 9999 (France = 3500, Others = 3000)
12
Maximum number of receiving lines
0 to 65535 (lines) Unlimited for 0
13
T.30 EOL timer
500 to 3000 (Default: 55s)
15
Threshold for hooking and on-hook
0 to 999
16
Time to temporarily response at FAX/TEL switching
0 to 9
17
Pseudo RBT cadence ON time
0 to 999
18
Pseudo RBT cadence OFF time (short)
0 to 999
19
Pseudo RBT cadence OFF time (long)
0 to 999
20
Pseudo ring tone cadence ON time
0 to 999
21
Pseudo CI cadence OFF time (short)
0 to 999
22
Pseudo CI cadence OFF time (long)
0 to 999
23
CNG detection level at FAX/TEL switching
0 to 7
24
Pseudo RBT delivery level at FAX/TEL switching
10 to 20 (100V),
0 to 20 (120/ 230V)
25
CNG monitoring time when answer phone is used
0 to 999
26
Level to detect no-sound when answer phone is used
0 to 7
27
Preamble detection time of V21 low-speed flag
20 (* 10ms)
51
Threshold value of hook detection
10 to
53
Set the number of DTMF ringing times at FAX remote reception
10 to (Default: 25)
54
Set the transmission time of BusyTone when the handset is used
55
Cycle to obtain data of environment log
0 to 480 min (Default: 60min) (No data is obtained with 0)
56
Select counter type to be displayed at counter 1
101
57
Select counter type to be displayed at counter 2
0 to 999
58
Select counter type to be displayed at counter 3
0 to 999
59
Select counter type to be displayed at counter 4
0 to 999
60
Select counter type to be displayed at counter 5
0 to 999
61
Select counter type to be displayed at counter 6
0 to 999
74
Port number of e-RDS RGW
75
Transmission interval of e-RDS for 3rd party
Item
Function
Setting Range
TONE
01
Tone signal delivery time (PSTN)
10 to 9999 (ms)
02
Minimum pause time (PSTN)
10 to 9999 (ms)
PULSE
PULSE FORM
Pulse digit format
0 -> DP (N)
1 -> DP (N + 1)
2 -> DP (10 - N)
01
Pulse dial speed (10 pps)
5 to 300 (x 0.1 pps)
03
Pulse dial make ratio
10 to 90 (%)
04
Minimum pause time
10 to 9999 (ms)
Summary of Contents for iR C1020 Series
Page 1: ...Sep 8 2008 Service Manual iR C1020 Series iR C1021i ...
Page 2: ......
Page 6: ......
Page 18: ...Contents ...
Page 19: ...Chapter 1 Introduction ...
Page 20: ......
Page 22: ......
Page 57: ...Chapter 2 Installation ...
Page 58: ......
Page 60: ......
Page 73: ...Chapter 3 Basic Operation ...
Page 74: ......
Page 76: ......
Page 81: ...Chapter 4 Main Controller ...
Page 82: ......
Page 84: ......
Page 97: ...Chapter 5 Original Exposure System ...
Page 98: ......
Page 100: ......
Page 112: ......
Page 113: ...Chapter 6 Original Feeding System ...
Page 114: ......
Page 116: ......
Page 132: ......
Page 133: ...Chapter 7 Laser Exposure ...
Page 134: ......
Page 136: ......
Page 143: ...Chapter 8 Image Formation ...
Page 144: ......
Page 146: ......
Page 180: ......
Page 181: ...Chapter 9 Pickup and Feed System ...
Page 182: ......
Page 213: ...Chapter 9 9 29 F 9 79 1 2 3 ...
Page 214: ......
Page 215: ...Chapter 10 Fixing System ...
Page 216: ......
Page 218: ......
Page 233: ...Chapter 11 External and Controls ...
Page 234: ......
Page 263: ...Chapter 12 e maintenance imageWARE Remote ...
Page 264: ......
Page 266: ......
Page 275: ...Chapter 12 12 9 F 12 27 ...
Page 280: ......
Page 281: ...Chapter 13 Maintenance and Inspection ...
Page 282: ......
Page 284: ......
Page 286: ......
Page 287: ...Chapter 14 Measurement and Adjustments ...
Page 288: ......
Page 290: ......
Page 293: ...Chapter 15 Correcting Faulty Images ...
Page 294: ......
Page 296: ......
Page 317: ...Chapter 16 Error Code ...
Page 318: ......
Page 320: ......
Page 331: ...Chapter 16 16 11 ...
Page 332: ......
Page 333: ...Chapter 17 Special Management Mode ...
Page 334: ......
Page 336: ......
Page 343: ...Chapter 17 17 7 ...
Page 344: ......
Page 345: ...Chapter 18 Service Mode ...
Page 346: ......
Page 348: ......
Page 388: ......
Page 389: ...Chapter 19 Upgrading ...
Page 390: ......
Page 392: ......
Page 396: ...Chapter 19 19 4 3 Click Next F 19 4 4 Select a USB connected device and click Next F 19 5 ...
Page 397: ...Chapter 19 19 5 5 Click Start F 19 6 6 Click Yes F 19 7 Download will be started F 19 8 ...
Page 399: ...Chapter 19 19 7 ...
Page 400: ......
Page 401: ...Chapter 20 Service Tools ...
Page 402: ......
Page 404: ......
Page 407: ...Sep 8 2008 ...
Page 408: ......