0020-4452
T-16-2
Code
Description
Action
E000
Error in start-up of fixing assembly
0000 Description
When 1 sec passed after energization of the heater, the detected temperature of the
main thermistor is not 5 deg C or more (0 deg C at power on).
Cause
Disconnection of main thermistor, disconnection of fixing heater, error in DC
controller PCB.
- Check of the connector of the low-voltage power supply PCB
- Replacement of fixing film unit
- Replacement of DC controller PCB
E001
Error in overheating of fixing assembly
0000 Description
The status where the detected temperature of the main thermistor is 225 deg C (approx.
0.84V equivalent) or more is detected for 0.5 continuous sec or more.
Cause
Error in main thermistor, error in DC controller PCB.
- Check of the connector of the low-voltage power supply PCB
- Replacement of fixing film unit
- Replacement of DC controller PCB
0001 Description
The status where the detected temperature of the sub thermistor is 245 deg C (approx.
2.12V equivalent) or more is detected for 0.5 continuous sec or more.
Cause
Error in sub thermistor, error in DC controller PCB.
E003
Error in abnormally low temperature of fixing assembly
0000 Description
The status where the detected temperature of the main thermistor is 100 deg C (approx.
2.60V equivalent) or less is detected for 0.5 continuous sec or more.
Cause
Error in low-voltage power supply PCB, disconnection of main thermistor, error in DC
controller PCB.
- Replacement of low-voltage power supply PCB
- Replacement of fixing film unit
- Replacement of DC controller PCB
0001 Description
The status where the detected temperature of the sub thermistor is less than 100 deg C
(approx. 0.38V equivalent) is detected 0.5 continuous sec or more after energization
of the heater.
Cause
Error in sub thermistor, error in DC controller PCB.
- Check of the connector of the low-voltage power supply PCB
- Replacement of fixing film unit
- Replacement of DC controller PCB
E004
Error in fixing power supply drive circuit
0000 Description
Cannot detect the zero cross signal for the specified period or more.
Cause
Error in fixing control circuit block.
- Replacement of low-voltage power supply PCB
Summary of Contents for iR C1020 Series
Page 1: ...Sep 8 2008 Service Manual iR C1020 Series iR C1021i ...
Page 2: ......
Page 6: ......
Page 18: ...Contents ...
Page 19: ...Chapter 1 Introduction ...
Page 20: ......
Page 22: ......
Page 57: ...Chapter 2 Installation ...
Page 58: ......
Page 60: ......
Page 73: ...Chapter 3 Basic Operation ...
Page 74: ......
Page 76: ......
Page 81: ...Chapter 4 Main Controller ...
Page 82: ......
Page 84: ......
Page 97: ...Chapter 5 Original Exposure System ...
Page 98: ......
Page 100: ......
Page 112: ......
Page 113: ...Chapter 6 Original Feeding System ...
Page 114: ......
Page 116: ......
Page 132: ......
Page 133: ...Chapter 7 Laser Exposure ...
Page 134: ......
Page 136: ......
Page 143: ...Chapter 8 Image Formation ...
Page 144: ......
Page 146: ......
Page 180: ......
Page 181: ...Chapter 9 Pickup and Feed System ...
Page 182: ......
Page 213: ...Chapter 9 9 29 F 9 79 1 2 3 ...
Page 214: ......
Page 215: ...Chapter 10 Fixing System ...
Page 216: ......
Page 218: ......
Page 233: ...Chapter 11 External and Controls ...
Page 234: ......
Page 263: ...Chapter 12 e maintenance imageWARE Remote ...
Page 264: ......
Page 266: ......
Page 275: ...Chapter 12 12 9 F 12 27 ...
Page 280: ......
Page 281: ...Chapter 13 Maintenance and Inspection ...
Page 282: ......
Page 284: ......
Page 286: ......
Page 287: ...Chapter 14 Measurement and Adjustments ...
Page 288: ......
Page 290: ......
Page 293: ...Chapter 15 Correcting Faulty Images ...
Page 294: ......
Page 296: ......
Page 317: ...Chapter 16 Error Code ...
Page 318: ......
Page 320: ......
Page 331: ...Chapter 16 16 11 ...
Page 332: ......
Page 333: ...Chapter 17 Special Management Mode ...
Page 334: ......
Page 336: ......
Page 343: ...Chapter 17 17 7 ...
Page 344: ......
Page 345: ...Chapter 18 Service Mode ...
Page 346: ......
Page 348: ......
Page 388: ......
Page 389: ...Chapter 19 Upgrading ...
Page 390: ......
Page 392: ......
Page 396: ...Chapter 19 19 4 3 Click Next F 19 4 4 Select a USB connected device and click Next F 19 5 ...
Page 397: ...Chapter 19 19 5 5 Click Start F 19 6 6 Click Yes F 19 7 Download will be started F 19 8 ...
Page 399: ...Chapter 19 19 7 ...
Page 400: ......
Page 401: ...Chapter 20 Service Tools ...
Page 402: ......
Page 404: ......
Page 407: ...Sep 8 2008 ...
Page 408: ......