2
2
2-43
2-43
Technology > Laser Exposure System > Service Works > Points to note at servicing
Technology > Laser Exposure System > Service Works > Points to note at servicing
Service Works
■
Periodically replaced parts
There is no periodically replaced part.
■
Consumables
No.
Parts Name
Parts Number
Qty
Estimated Life
1
Dust-blocking Glass cleaning pad
FL2-9476
1
150k
■
Periodical service list
Parts name: Dust-blocking Glass
Expected life: per 50K sheet
Operation: Clean it with the Dust-blocking Glass Cleaning tool stored in the machine.
Dust-blocking glass
cleaning tool
■
Operation at parts replacement
N / A
■
Points to note at servicing
Do not install a used Laser Scanner Unit 2 (C/Bk laser) to the position where a Laser Scanner
Unit 1 (Y/M laser) should be installed.
With this machine, yellow laser is used as a reference to control other colors. This means
that the reference will be changed if the Laser Scanner Unit for YM side and that for CBk side
are replaced with each other. As a result of this, color displacement will occur and may not
be solved. Even if the units are returned after they were replaced with each other once, the
reference was changed when they were replaced, therefore color displacement will not be
solved.
T-2-25
F-2-61