4
4
4-172
4-172
Parts Replacement and Cleaning > Fixing System > Cleaning the Shutter Cover > Procedure
Parts Replacement and Cleaning > Fixing System > Cleaning the Shutter Cover > Procedure
Cleaning the Fixing Separation Guide
■
Preparations
1) Open the Right Lower Cover and Right Upper Cover.(Refer to page 4-175)
2) Remove the Fixing Unit.(Refer to page 4-167)
3) Remove the Film Unit.(Refer to page 4-169)
■
Procedure
1) Clean the Fixing Separation Guide with lint-free paper moistened with alcohol.
F-4-306
Cleaning the Shutter Cover
■
Preparations
1) Open the Right Lower Cover and Right Upper Cover.(Refer to page 4-175)
2) Remove the Fixing Unit.(Refer to page 4-167)
■
Procedure
NOTE:
When installing/removing it, do not touch the Film Unit and Pressure Roller.
1) Change the direction of the Fixing Assembly. (Place it in the position where the Drawer
connector side faces up.)
2) Remove the harness.
• 3 connectors
• Harness Guide [A]
Connectors
Drawer connector
Harness
x3
[A]
F-4-307