4
4
4-150
4-150
Parts Replacement and Cleaning > Image Formation System > Removing the Main Drive Unit > Preparations
Parts Replacement and Cleaning > Image Formation System > Removing the Main Drive Unit > Preparations
5) Pull out the toner container.
CAUTION:
At installation, make sure to insert the Toner Container all the way in and close the
small cover.
F-4-241
F-4-240
Removing the Main Drive Unit
■
Preparations
1) Open the Right Lower Cover and Right Upper Cover.(Refer to page 4-175)
2) Remove the Right Rear Cover.(Refer to page 4-147)
3) Remove the Left Rear Cover and the Left Rear Sub Cover.(Refer to page 4-147)
4) Remove the Connector Cover.
• 1 screw
5) When the Cassette Pedestal is installed, remove the connector.
• 1 reuse band
• 6 harness guides
• 5 connectors
Harness Guides
Connectors
Connectors
x5
x7
Reuse Band
F-4-242
F-4-243