Parts Replacement and Cleaning > Image Formation System > Removing the Process Unit > Procedure
Parts Replacement and Cleaning > Image Formation System > Removing the Process Unit > Procedure
3) Pull out the Process Unit until it stops.
• 2 screws
x2
4) Place the paper onto the Process Unit to protect the Drum Unit from the light.
Paper
F-4-185
F-4-186
Removing the Process Unit
■
Preparations
1) Open the Front Cover, Right Lower Cover and Right Upper Cover.(Refer to page 4-104)
2) Remove the ITB Cover.(Refer to page 4-104)
3) Pull out the Process Unit.(Refer to page 4-131)
■
Procedure
CAUTION:
When installing/removing the Process Unit, do not remove the Recycle Toner Bottle.
1) Remove the 4 stepped screws fixed on the right and left rails.
x4
2) Hold the front and rear of Process Unit and remove it flatly.
F-4-187
F-4-188