Cleaning the Shutter Cover
■
Preparations
1) Open the Right Lower Cover and Right Upper Cover.
2) Remove the Fixing Unit.
■
Procedure
NOTE:
When installing/removing it, do not touch the Film Unit and Pressure Roller.
1) Change the direction of the Fixing Assembly. (Place it in the position where the Drawer
connector side faces up.)
2) Remove the harness.
• 3 connectors
• 6 harness guides
Connectors
Drawer connector
Harness guides
Harness guides
Harness
x3
x8
F-4-281
3) Remove the Shutter Unit.
• 4 screws
x4
4) Clean the Shutter Cover with lint-free paper moistened with alcohol.
F-4-282
F-4-283