2
2
2-158
2-158
Technology■>■MEAP■>■MEAP■Safe■Mode■(level■2)■>■Starting■in■Safe■Mode
Technology■>■MEAP■>■MEAP■Safe■Mode■(level■2)■>■Starting■in■Safe■Mode
MEAP■Safe■Mode■(level■2)
■
■
Outline
Use■safe■mode■if■you■need■to■start■up■the■system■without■worrying■about■extra■applications.■It■
will■start■up■only■those■system■software■files■(including■SMS)■that■normally■start■up■as■default■
files■while■preventing■MEAP■applications■and■the■like■from■starting■up.
When■you■have■made■changes■and■restart■the■device,■the■control■panel■will■indicate■'MPSF'■
in■its■lower■right■corner.■The■MEAP■applications■that■may■have■been■active■before■you■shut■
down■the■equipment■will■not■start■up■on■their■own.■Make■use■of■safe■mode■when■restoring■
the■system■software■as■when■MEAP■applications■or■services■cause■a■fault■as■the■result■of■a■
conflict■or■wrong■sequence■of■registration/use.■You■can■access■to■SMS■in■this■condition■so■
that■you■can■take■necessary■measures,■for■example,■you■can■stop■application■that■may■cause■
the■trouble.
If■default■authentication■has■been■selected,■the■mode■of■authentication■remains■valid;■
otherwise,■the■message■"The■login■service■must■be■set■again■with■SMS"■ap■pears.■Change■
the■login■service■as■necessary.
■
■
Starting■in■Safe■Mode
1)■Startup■[SERVICE■MODE]■in■level■2.
2)■Press■[COPIER]■>[Option]■>■[USER]■buttons.
F-2-237
3)■Press■
■or■
■button■for■several■times■until■[MEAPSAFE]■button■is■shown.■Click■
[MEAPSAFE]■button.
4)■Press■the■1■key■on■the■control■panel■keypad■to■change■the■setting■to■'1';■then,■click■[OK]■
button.
5)■Check■that■the■notation■‘MPSF’■has■appeared■in■the■upper■left■corner■of■the■screen;■then,■
restart■the■device.
F-2-238
F-2-239
F-2-240