R. Periodic Maintenance
The parts in the table below must be periodically: replaced, cleaned, inspected
or adjusted to ensure a specific level of machine performance. These parts are
likely to affect the performance once they fail even in the absence of external
change or damage. Whenever possible, plan periodic maintenance so that it will
coincide with a scheduled service visit.
Table 33 – Main Unit Periodic Maintenance
Main Unit Periodic Maintenance
Part Name
Estimated Interval
Remarks
120,000
500,000
600,000
1,000,000 6,000,000
As
needed
♦
:Replacement (Periodical replacement)
●: Replacement (Consumable parts)
Δ: Cleaning ×: Lubrication
Primary Charging
Assembly
●
Primary Charging Wire
♦
In a high temperature/humidity
environment (30 deg C/80%),
replace at 250,000 sheets.
Primary Charging Wire
cleaner
♦
Primary Charging Wire
cleaner holder
♦
Grid Wire
♦
Pre-transfer Charging
Assembly
●
Pre-transfer Charging
Wire
♦
In a high temperature/humidity
environment (30 deg C/80%),
replace at 250,000 sheets.
Pre-transfer Charging
Wire cleaner
♦
Pre-transfer Charging
Wire cleaner holder
♦
Developing Cylinder
●
Developing Roller
●
Drum Cleaning Blade
●
Reverse the blade every
300,000 sheets (single-sided).
Drum Separation Claw
●
Drum Front Side Seal
●
Drum Rear Side Seal
●
Scraper
●
Δ
Clean with lint-free paper
moistened with alcohol.
Dustproof Glass
Δ
Drum Cleaning Unit
Plate
Δ
Value is based on LTR sized paper. Estimated average values in the field, based on data from supplier. Data is subject to change
depending upon many factors including, without limitation, monthly copy volume, environment, type of image printed and customer