4
4
4-139
4-139
Parts Replacement and Clearning > Image Formation System > Removing the ETB
Parts Replacement and Clearning > Image Formation System > Removing the ETB
Removing the ETB
<Preparation>
1. Pull out the Fixing Feed Unit. (Refer to "Removing the ETB Unit")
2. Remove the ETB Unit. (Refer to page 4-137)
CAUTION:
Do not touch the surface of the ETB when handling the ETB Unit.
<Procedure>
1) Fold the ETB Drive Roller Unit.
• 2 Screws
x2
F-4-193
2) Set up the ETB Unit to remove the Roller Unit from the ETB.
CAUTION:
• Be sure to hold within 10mm from both edges of the ETB when handling the ETB.
• Do not touch the surface of the ETB Drive Roller and the Transfer Roller; otherwise,
it can cause image faults.
F-4-194