Parts Replacement and Cleaning > Consumable Parts Requiring Periodic Replacement > Removing the Manual Feed Separation Pad
Parts Replacement and Cleaning > Consumable Parts Requiring Periodic Replacement > Removing the Manual Feed Separation Pad
2) Release the claws, and then slide the bearing (front).
3) Remove the manual feed pickup roller.
x1
Claw
MEMO:
Reassemble the manual feed pickup roller as shown.
F-4-89
F-4-88
Removing the Manual Feed Separation Pad
1) Remove the manual feed pickup roller. (
“Removing the Manual Feed Pickup Roller”(page
)
2) Slide the bearing (rear) backward.
x1
3) Remove the separation pad with a flat-blade screwdriver.
F-4-90
F-4-91