Error Code
Error Code Details
Ecode
Detail Code
Item
Description
E000
0001
Title
Fixing temperature abnormal rise
Description
The temperature detected by the main thermistor does not rise to
the specified value during startup control.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
E001
0000
Title
Fixing unit temperature rise detection
Description
The reading of the main thermistor is 250 deg C or more continu-
ously for 200 msec.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
E001
0001
Title
Fixing unit temperature rise detection
Description
The hardware circuit detects overheating of the main or sub ther-
mistor for 200 msec.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Replace the DC Controller PCB (PCB4).
E001
0002
Title
Fixing unit temperature rise detection
Description
The reading of the sub thermistor is 295 deg C or more continu-
ously for 200 msec.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
E002
0000
Title
Fixing unit temperature insufficient rise
Description
1.The reading of the main thermistor is less than 115 deg C con-
tinuously for 400 msec 1.3 sec after it has indicated 100 deg C.
2.The reading of the main thermistor is less than 150 deg C con-
tinuously for 400 msec 1.3 sec after it has indicated 140 deg C.
Remedy
1.Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR; and then turn OFF and then ON the power.
2.Check connection of the Connectors (Thermistor Connector and
AC Connector).
3.Replace the Fixing Main Thermistor (Film Unit).
4.Replace the Fixing Assembly.
5.Replace the DC Controller PCB (PCB4).
E003
0000
Title
Low fixing temperature detection after standby
Description
The reading of the main thermistor is less than 140 deg C contin-
uously for 400 msec or more.
7. Error/Jam/Alarm
201
Summary of Contents for imageRUNNER 2525 Series
Page 1: ...Revision 9 0 imageRUNNER 2530 2525 2520 Series Service Manual ...
Page 62: ...No Part name 3 Laser unit 2 Technical Explanation 52 ...
Page 119: ...Periodical Service 3 Consumable Parts and Cleaning Parts 110 Cleaning Parts 115 ...
Page 125: ...Cleaning Parts Fixing guide Transfer guide 3 Periodical Service 115 ...
Page 136: ...List of Sensors S18 S17 S16 TS2 HU1 S9 S8 S19 TS1 S11 S12 4 Disassembly Assembly 126 ...
Page 165: ...5 Remove the idler gear 1 claw 1x 4 Disassembly Assembly 155 ...
Page 172: ... 1 4 2 3 2 2 Remove the scanner motor 4 screws 4x 4 Disassembly Assembly 162 ...
Page 186: ...3 Remove the RAM PCB Release the hook 4 Disassembly Assembly 176 ...
Page 187: ...Adjustment 5 Overview 178 Basic Adjustment 180 Adjustment when Replacing the Parts 182 ...
Page 209: ...Error Jam Alarm 7 Outline 200 Error Code 201 Jam Code 213 Alarm Code 219 ...
Page 231: ...Service Mode 8 Overview 222 Details of Service Mode 225 Remote UI Service Mode 302 ...
Page 314: ...Example of report display 8 Service Mode 304 ...
Page 387: ...APPENDICES Service Tools 378 General Circuit Diagram 379 ...