Procedure
NOTE:
The following describes the procedure to upgrade Boot as an example: For upgrading the other firmware, follow the same
procedure as Boot.
CAUTION:
When upgrading the system software of Boot and Bootable lang, be sure to first upgrade Boot.
1. Turn ON the Power Switch of the PC and start UST.
2. When turning On the Power Switch, a wizard is displayed to add a new hardware, and click "Cancel".
3. Enter service mode.
4. Press the arrow key and select "DOWNLOAD", and then press the OK key.
NOTE:
Download Mode is also available from the following user mode:
> System Settings > Update Firmware > Yes
5. Start UST once "USB DOWNLOAD AVAILABLE" is displayed.
6. Following the instruction on the screen, select "Next".
6. Troubleshooting
195
Summary of Contents for imageRUNNER 2520 Series
Page 1: ...Revision 9 0 imageRUNNER 2530 2525 2520 Series Service Manual ...
Page 62: ...No Part name 3 Laser unit 2 Technical Explanation 52 ...
Page 119: ...Periodical Service 3 Consumable Parts and Cleaning Parts 110 Cleaning Parts 115 ...
Page 125: ...Cleaning Parts Fixing guide Transfer guide 3 Periodical Service 115 ...
Page 136: ...List of Sensors S18 S17 S16 TS2 HU1 S9 S8 S19 TS1 S11 S12 4 Disassembly Assembly 126 ...
Page 165: ...5 Remove the idler gear 1 claw 1x 4 Disassembly Assembly 155 ...
Page 172: ... 1 4 2 3 2 2 Remove the scanner motor 4 screws 4x 4 Disassembly Assembly 162 ...
Page 186: ...3 Remove the RAM PCB Release the hook 4 Disassembly Assembly 176 ...
Page 187: ...Adjustment 5 Overview 178 Basic Adjustment 180 Adjustment when Replacing the Parts 182 ...
Page 209: ...Error Jam Alarm 7 Outline 200 Error Code 201 Jam Code 213 Alarm Code 219 ...
Page 231: ...Service Mode 8 Overview 222 Details of Service Mode 225 Remote UI Service Mode 302 ...
Page 314: ...Example of report display 8 Service Mode 304 ...
Page 387: ...APPENDICES Service Tools 378 General Circuit Diagram 379 ...