9
9
9-23
9-23
Installation > Installation > Installing the developing assembly
Installation > Installation > Installing the developing assembly
Installing the developing assembly
1) Hold the grip and open the process unit
upper cover.
• 2 screws (The removed screws will
be used in step 10).)
2) Turn the lock lever in the direction of
arrow, and then lock the process unit
upper cover.
x2
TOP VIEW
F-9-50
3) Place A3 paper on the drum.
NOTE :
To protect the photosensitive
drum.
F-9-51
4) Remove the 2 developing pressure fixing tapes.
F-9-52