4
4
4-82
4-82
Disassembly/Assembly > Original Exposure/Feed System (Copyboard Model) > Removing the Flat Bed Motor Unit (Copyboard Model) > Procedure
Disassembly/Assembly > Original Exposure/Feed System (Copyboard Model) > Removing the Flat Bed Motor Unit (Copyboard Model) > Procedure
Removing the Flat Bed Motor Unit (Copyboard Model)
■
Preparation
●
Duplex Model
1) Remove the Left Cover (Duplex Model) (Refer to page 4-86).
2) Removing the Copyboard Cover + Reader Unit (Refer to page 4-76).
3) Remove the Copyboard Cover (Refer to page 4-75).
4) Remove the Copyboard Glass (Copyboard Model) (Refer to page 4-78).
●
Sinplex Model
1) Remove the Left Cover (Sinplex Model)(Refer to page 4-144).
2) Removing the Copyboard Cover + Reader Unit (Refer to page 4-76).
3) Remove the Copyboard Cover (Refer to page 4-75).
4) Remove the Copyboard Glass (Copyboard Model) (Refer to page 4-78).
F-4-211
■
Procedure
CAUTION:
• Do not lose the 2 spacers [1] of the Contact Image Sensor Unit.
• Do not touch the document reading part [A] of the Contact Image Sensor Unit.
[1]
[A]
F-4-212
1) Move the Contact Image Sensor Unit [1].
[1]
F-4-213