7
7
7-3
7-3
Error Codes > Error Codes
Error Codes > Error Codes
Error Codes
Code
Detection description
Remedy
E000 0000
Fixing Assembly does
not start up within
specified time.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check that the heater resistance measured between
1PIN and 2PIN of the cable (J101) on the DC Controller
Board is in the following range. Replace the Fixing
Assembly when the resistance value is abnormal.
[1] 120 V machine - Heater resistance: 16.0 Ω ±7%
[2] 230 V machines - Heater resistance: 53.8 Ω ±7%
(2) Check the connection of connector (J101) on the DC
Controller Board.
(3) Check the connection of connector (J552) on DC
Controller Board.
(4) Replace the Fixing Assembly.
(5) Replace the DC Controller Board.
E001 0000 Abnormal high-
temperature detection
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check that the heater resistance measured between
1PIN and 2PIN of the cable (J101) on the DC Controller
Board is in the following range. Replace the Fixing
Assembly when the resistance value is abnormal.
[1] 120 V machine - Heater resistance: 16.0 Ω ±7%
[2] 230 V machines - Heater resistance: 53.8 Ω ±7%
(2) Check the connection of connector (J101) on the DC
Controller Board.
(3) Check the connection of connector (J552) on DC
Controller Board.
(4) Replace the Fixing Assembly.
(5) Replace the DC Controller Board.
E003 0000 Abnormal low-
temperature detection
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check that the heater resistance measured between
1PIN and 2PIN of the cable (J101) on the DC Controller
Board is in the following range. Replace the Fixing
Assembly when the resistance value is abnormal.
[1] 120 V machine - Heater resistance: 16.0 Ω ±7%
[2] 230 V machines - Heater resistance: 53.8 Ω ±7%
(2) Check the connection of connector (J101) on the DC
Controller Board.
(3) Check the connection of connector (J552) on DC
Controller Board.
(4) Replace the Fixing Assembly.
(5) Replace the DC Controller Board.
Code
Detection description
Remedy
E004 0000 Fixing power supply
drive circuit error
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Replace the DC Controller Board.
(2) Replace the Fixing Assembly.
E100 0001
Error detection on any
of scanner motor, laser
unit, and BD detection
at scanner area.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Replace the Laser Scanner Unit.
(2) Replace the DC Controller Board.
E196 2000
ROM read/write error
(Error in storing each
setting values for user
mode / service mode /
factory mode)
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Update the set of the Controller Firmware
(2) Replace the Main Controller Board.
E202 0002 Contact Sensor HP
error, Failure in return
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check the connection of Flat Cable between Main
Controller Board (J5) and Contact Sensor.
(2) Replace the Flat Cable between Main Controller Board
(J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
E225 0001
Light intensity of a lamp
is less or equal to the
criteria
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check the connection of Flat Cable between Main
Controller Board (J5) and Contact Sensor.
(2) Replace the Flat Cable between Main Controller Board
(J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
E301 0001 Insufficient light intensity
in shading
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check the connection of Flat Cable between Main
Controller Board (J5) and Contact Sensor.
(2) Replace the Flat Cable between Main Controller Board
(J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.