![Canon FY8-13FW-000DADF-A1 Service Manual Download Page 127](http://html1.mh-extra.com/html/canon/fy8-13fw-000dadf-a1/fy8-13fw-000dadf-a1_service-manual_4137855127.webp)
CHAPTER 5 TROUBLESHOOTING
5-20
COPYRIGHT © 1998 CANON INC. CANON DADF-A1 REV.0 DEC. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
II. TROUBLESHOOTING
A. Troubleshooting Malfunctions
1. E400/E712
Table 5-201
Parts
Wiring
DADF
controller
PCB
Step
1
2
3
Action
End. (Check the wiring
between the copier's DC
controller PCB and the
DADF controller PCB.)
Check the wiring for power
from the copier.
End.
Replace the copier's DC
controller PCB.
Checks
Turn off and then on the
power switch. Is the
problem corrected?
Set the meter range to
200 VDC, and connect
the meter probes as
indicated. Is the voltage
about 24 V?
Replace the DADF
controller PCB. Is the
problem corrected?
Yes/No
YES
NO
YES
NO
+ probe
J2-1
J1-6
- probe
J2-2
1
2