3-58
COPYRIGHT © CANON ELECTRONICS INC. 2008
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
IX. UPPER UNIT-4 (READING SYSTEM)
Note:
If the reading unit is disassembled fur-
ther, be careful to prevent entry of dust.
Do not touch the inner surfaces of glass
and the surfaces of the lens array with
fingers. If they are dirty, clean them with
a clean dry cloth.
If the inside is not disassembled, re-
place the entire reading unit.
Note:
The differences between the parts of the
reading unit (upper) and the reading unit
(lower) are the cable cover and flat ca-
ble. The wiring of some cables and the
direction of assembly are different.
1. Reading Unit
1) Remove the eject tray unit.
2) Remove 2 cables
{
1
(for the blower) from
the main drive PCB.
Note:
If the cable is connected, the reading
unit cannot be removed.
Figure 3-901
3) Remove the platen roller.
4) Remove the reading rollers (center and
rear).
5) Remove 2 screws
{
1
(M3, TP head) and
remove the reading unit
{
2
.
Note:
Do not pull it excessively because a
cable is connected to it.
Coil springs are mounted on the bottom
side of the reading unit fixing part. Do
not lose it.
Figure 3-902