Chapter 3
3-14
3.3.4 Original Size Detection 2
0013-3471
A. Outline
In original size detection 2, the original width detecting switch (SW301) and the registration roller clock sensor
(PI5) are used to identify a default size.
The original width detecting switch is designed to find out the width of originals. As many as five contact plates
(SSW0 through 4) are in contact with the original width detecting switch, operating in keeping with the slide
guide. The state (ON or OFF) of each contact plate is communicated to the ADF controller PCB, which uses the
input to determine the width of the original.
The following table shows the states of the contact plates in relation to default sizes; the states other than those
indicated are assumed to indicate the presence of an original which is not of a default size.
F-3-16
T-3-3
Default size
SSW0
SSW1
SSW2
SSW3
SSW4
A5, A4R
ON
ON
OFF
ON
ON
ON
OFF
OFF
ON
ON
A4, A3
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
B5R
ON
OFF
OFF
OFF
ON
B5, B4
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
OFF
STMT, LTRR, LGL
ON
ON
ON
OFF
ON
ON
ON
OFF
OFF
ON
LTR, 279.4 X 431.8 mm (11" X 17")
ON
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
Slide guide
ADF controller PCB
ON/OFF
Original width
detecting switch (SW301)
Summary of Contents for DADF-R1
Page 2: ......
Page 4: ......
Page 12: ...Contents 6 3 Alam Code 6 6 6 3 1 List of Alarm Code 6 6 ...
Page 13: ...Chapter 1 SPECIFICATIONS ...
Page 14: ......
Page 16: ......
Page 22: ......
Page 23: ...Chapter 2 INSTALLATION ...
Page 24: ......
Page 26: ......
Page 55: ...FUNCTIONS Chapter 3 ...
Page 56: ......
Page 67: ...Chapter 3 3 9 F 3 11 Reversing Copying the 2nd side Delivering From previous page ...
Page 121: ...PARTS REPLACEMENT PROCEDURE Chapter 4 ...
Page 122: ......
Page 124: ......
Page 145: ...MAINTENANCE Chapter 5 ...
Page 146: ......
Page 200: ......
Page 201: ...ERROR CODE Chapter 6 ...
Page 202: ......
Page 204: ......
Page 211: ...APPENDIX ...
Page 212: ......
Page 221: ......
Page 222: ......