Chapter 3
3-12
3.3.2 Detecting the Presence/Absence of an Original
0013-3469
The presence/absence of an original in the original tray is detected by the original sensor (S6).
When an original is placed on the original tray, the light from the light-emitting side of the original sensor is
blocked, causing the light-receiving side of the original sensor to send the original detection signal (DTS) to the
ADF controller PCB, which in response turns on the Original Set indicator.
F-3-14
ADF controller PCB
S6
(light-receiving side)
S6
(light-emitting side)
S6
(light-receiving side)
ADF controller PCB
When an original is detected
When no original is detected
S6
(light-emitting side)
S6
(light-receiving side)
ADF controller PCB
DTS signal
DTS signal
Original
Light is blocked.
S6
(light-emitting side)