20
Carrying the Product
When carrying the product, hold the upper handle (1) or hold the two lower handles (2) simultaneously.
Mounting the Head Unit
Prepare a bracket matching the dimensions of the four M6 taps on the bottom surface.
Use steel screws with a bolt length equivalent to the bracket thi 15 to 20 mm, and fix it by tightening torque of 2 to
4.9 N · m (20 to 50 kg · cm).
Use a level to check that the base is horizontal.
Installation in a High Place
When there is a risk of falling, such as installation in a high place or mounting on the ceiling, be sure to insert a
commercially available safety wire that can withstand the total weight including the camera and mounting bracket
through the two through-holes and secure the wire to a sturdy structure.
Installation
(1)
(2)
(2)