94
S
360 Audio Video synchronize error [err]
S
430 Temperature sensor failure [crit]
Audio server error
B301 Audio device error [err]
B402 Audio server initialization failed [err]
B403
S
ettings change failed [err]
Video error
V400 Video input initialization error [crit]
V401 Video input command error [crit]
V402 Video input frozen [crit]
Standard communication (IP)
error
D401
S
tandard communication (IP)
initialization failed [crit]
Description
Audio Video synchronize error. (S360)
Meaning
Video/Audio synchronize error
Countermeasure
If the error is still detected after
rebooting, it may be a failure, so contact
the dealer.
Description
cannot get temperature (S430)
Meaning
Cannot get the temperature from the
temperature sensor.
Countermeasure
If the error is still detected after
rebooting, it may be a failure of the
board, so contact the dealer.
Description
cannot use audio device for %1
[%2:%3] (B301)
%1
Send/Receive type (rx | tx)
%2
Error type (open | write | flush)
%3
Error number
Meaning
Detected an error in the audio device.
Countermeasure
If the error is still not cleared, contact
the dealer.
Description
wvaudio initialization error [%1] (B402)
%1
Error number
Meaning
The audio server could not be initialized.
The audio server stops.
Countermeasure
If the error is still detected after
rebooting, it may be a failure, so contact
the dealer.
Description
cannot set config [%1:%2] (B403)
%1
Error notification number
%2
Error number
Meaning
The settings could not be updated. The
audio server stops.
Countermeasure
If the error is still detected after
rebooting, it may be a failure, so contact
the dealer.
Description
video %1 initialization failure - %2 (%3)
(V400)
%1
Video number
%2
Process description
%3
Error details
Meaning
The video input function was stopped
because the video input system could
not be initialized.
Countermeasure
If the error is still detected after
rebooting, it may be a failure, so contact
the dealer.
Description
video command error - %1 (V401)
%1
Procedure details
Meaning
The video input function was stopped
because a video input command could
not be processed. Or, it may not
operate in the desired setting.
Countermeasure
If the error is still detected after
rebooting, it may be a failure, so contact
the dealer.
Description
video %1 stalled (V402)
%1
Video number
Meaning
The video input function was stopped
because the video input from the
camera stopped.
Countermeasure
If the error is still detected after
rebooting, it may be a failure, so contact
the dealer.
Description
Standard Com initialization error[%1]
(D401)
%1
Error number
Meaning
Standard communication (IP) could not
be initialized.
Countermeasure
If the error is still detected after
rebooting, it may be a failure, so contact
the dealer.