![Canon Color imageCLASS MF8580Cdw Service Manual Download Page 387](http://html1.mh-extra.com/html/canon/color-imageclass-mf8580cdw/color-imageclass-mf8580cdw_service-manual_4114784387.webp)
8
8
8-39
8-39
Service Mode > FAX > Setting of NCU Parameters > TONE/PULSE
Service Mode > FAX > Setting of NCU Parameters > TONE/PULSE
Numeric parameter setting mode
M82 M85
No.
Parameter
Allowable setting range
53
Set DTMF calling counts when receiving FAX
remotely
10 to 9999 (default 25)
○
○
54
Set Busy Tone outgoing duration when using handset
○
○
55 - 80 Not in use
-
-
T-8-31
Setting of NCU Parameters
■
TONE/PULSE
Operation Method
1) Setting of Tone Parameters
While "#NCU" is displayed, press "OK" key -> Select "#TONE" and press "OK" key so that
it becomes tone parameter setting mode.
2) Setting of Pulse Parameters
While "#NCU" is displayed, press "OK" key -> Select "#PULSE" and press "OK" key so that
it becomes pulse parameter setting mode.
Item
Function
Setting range
M82 M85
TONE
01; Tone signal sending time
(PSTN)
10 to 9999 (msec)
○
○
02; Minimum pause time (PSTN) 10 to 9999 (msec)
○
○
PULSE PULSE FORM
Pulse digit format
0 -> DP (N)
1 -> DP (N+1)
2 -> DP (10-N)
○
○
PULSE NUM 01;
-
-
-
-
02;
-
-
-
-
03; Pulse dial make ratio
10 to 90 (%)
○
○
04; Minimum pause time
10 to 9999 (msec)
○
○
T-8-32
Summary of Contents for Color imageCLASS MF8580Cdw
Page 317: ...5 5 Adjustment Adjustment Overview Adjustment at Parts Replacement...
Page 340: ...7 7 Error codes Error codes Overview Error Codes Jam Code...
Page 349: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE...
Page 394: ...Special Tools Solvents and Oils General Circuit Diagram Backup Data Appendex...