![Canon Color imageCLASS MF8580Cdw Service Manual Download Page 386](http://html1.mh-extra.com/html/canon/color-imageclass-mf8580cdw/color-imageclass-mf8580cdw_service-manual_4114784386.webp)
8
8
8-38
8-38
Service Mode > FAX > List of NUM
Service Mode > FAX > List of NUM
List of MENU
Menu switch registration mode
M82 M85
No.
Parameter
Selection
01 - 04 Not in use
-
-
05
-
-
-
-
06
Telephone line monitor
0 - 3
0: DIAL, 1: SERVICEMAN1, 2:
SERVICEMAN2, 3: OFF
○
○
07
Transmission level (ATT)
0 - 15
○
○
08
Upper limit of V.34 modulation speed 0 - 5
0: 3429 BAUD, 1: 3200 BAUD, 2: 3000
BAUD, 3: 2800 BAUD, 4: 2743 BAUD, 5:
2400 BAUD
○
○
09
Upper limit of V.34 data speed
0-13
0: 33.6 kbps, 1: 31.2 kbps, 2: 28.8 kbps, 3:
26.4 kbps, 4: 24.0 kbps, 5: 21.6 kbps, 6:
19.2 kbps, 7: 16.8 kbps, 8: 14.4 kbps, 9:
12.0 kbps, 10: 9.6 kbps, 11: 7.2 kbps, 12:
4.8 kbps, 13: 2.4 kbps
○
○
10
OFF Hook signal frequency
0-2
0: 50 Hz, 1: 25 Hz, 2: 17 Hz
○
○
11 - 20 Not in use
-
-
T-8-30
List of NUM
Numeric parameter setting mode
M82 M85
No.
Parameter
Allowable setting range
01
Not in use
-
-
02
RTN transmission criteria X
1 to 99 %
○
○
03
RTN transmission criteria n
2 to 99 times
○
○
04
RTN transmission criteria m
1 to 99 lines
○
○
05
NCC pause (before ID code)
1 to 60 sec
○
○
06
NCC pause (after ID code)
1 to 60 sec
○
○
07
Spare
-
-
08
STORED_DIAL_MODE wait timer
0 to 65 sec
○
○
09
Not in use
-
-
10
T.30 T0 timer
55 sec principally
○
○
11
T.30 T1 timer (for incoming transmission)
0 to 9999
(France: 3500, Others:
3000)
○
○
12
Maximum incoming lines
0 to 65535 (line)
0: without limitation
○
○
13
T.30 EOL timer
500 to 3000
(set to 55 sec by default) ○
○
14
Not in use
-
-
15
Threshold between hokking nad on-hook
0 to 999
○
○
16
Lead time to the first response when switching
between FAX and TEL
0 to 9
○
○
17
Duration to activate pseudo-RBT cadence
0 to 999
○
○
18
Duration to deactivate pseudo-RBT cadence (short) 0 to 999
○
○
19
Duration to deactivate pseudo-RBT cadence (long)
0 to 999
○
○
20
Duration to activate pseudo-ring cadence
0 to 999
○
○
21
Duration to deactivate OFF Hook cadence (short)
0 to 999
○
○
22
Duration to deactivate OFF Hook cadence (long)
0 to 7
○
○
23
-
-
-
-
24
-
-
-
-
25
CNG monitor duration while the answering device is
activated
0 to 999
○
○
26
-
-
-
-
27
-
-
-
-
28
Not in use
-
-
29
Off-hook PCB duty settings
(For NAC, setting can be made with SPL71100 in
special management mode.)
20 (*10ms)
○
○
30 - 48 Not in use
-
-
49
NSX MODEL ID
0 to 4095
○
○
50
Not in use
-
-
51
Threshold to detect hook
10 to 9999
○
○
52
Not in use
-
-
Summary of Contents for Color imageCLASS MF8580Cdw
Page 317: ...5 5 Adjustment Adjustment Overview Adjustment at Parts Replacement...
Page 340: ...7 7 Error codes Error codes Overview Error Codes Jam Code...
Page 349: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE...
Page 394: ...Special Tools Solvents and Oils General Circuit Diagram Backup Data Appendex...