![Canon Buffer Pass Unit-N1 Service Manual Download Page 12](http://html.mh-extra.com/html/canon/buffer-pass-unit-n1/buffer-pass-unit-n1_service-manual_62256012.webp)
Basic Configuration
Basic Constitution
The buffer unit consists of the following major components:
PS402
PS403
PS401
M401
PCB401
Symbol
Name
PS401
Buffer Pass Inlet Sensor
PS402
Buffer Pass Exit Sensor
PS403
OPEN Detection Sensor
PCB401
Buffer Pass Controller PCB
M401
Buffer Pass Feed Motor
Overview of Electrical Circuitry
The buffer pass operation sequence is controlled by the buffer pass controller PCB.
The buffer pass controller PCB has a 32-bit CPU that performs sequence control.
The buffer pass controller PCB receives various commands through the communication cable from its host to drive the motors.
It also sends sensor information to its host through the communication cable.
Finisher
Controller PCB
Host Machine
Motor
Sensor
UFDI
Communication
UFDI
Communication
Buffer Pass
Controller PCB
Related service mode
• (Lv.1) COPIER > DISPLAY > VERSION > BF-PASS
Related error code
• E503-0041: Error in communication between the Finisher and Buffer Pass
• E503-0042: Error in communication between the Finisher and Buffer Pass
2. Technical Explanation