Canoga Perkins L357 ESU Quick Start Manual Download Page 1

Quick Start Guide 

L357 ESU

 

 

Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 

Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com 

P/N 6942590 Rev A  

 

Page 1 of 8

 

 

 

 
 
 
 

Overview 

This document provides instructions for installation and initial configuration of the Canoga 
Perkins model L357 ESU (Ethernet Service Unit).  

The EdgeAccess L357 Ethernet Service Unit 

is a managed Ethernet and Fast Ethernet Compliant device that supports native 10Mbps, 
100Mbps and 1000Mbps Transparent LAN extension circuits. The L357 offers 10/100/1000 auto 
sensing or software configurable User Interface and a variety of optical network interfaces. The 
L357 is modular and hot swappable with a common form factor to mount in Canoga Perkins’ 
Carrier Class Universal Chassis System (UCS) as well as a variety of Customer Premise 
Enclosures (CPE).

 

 

 

Parts List 

1 x L357-xxxx 
1 x UCS 1000 or UCS 1002 chassis 
1 x UCS 1001 chassis 
1 x UCS 1230 BAM (Bus Access Module) 
1 x Model 1020-xxxx (management access CPE) or 1030-xxxx (unmanaged CPE) 
1 x EIA-232 serial cable (straight) 
1 x EIA-232 to DB9 converter (Canoga Perkins p/n CRJ-D9F-10) 

 

Step 1:  Unpacking 

Unpack the L357 and check the unit for damage.  If the unit is damaged, contact Canoga Perkins’ 
Tech Support line, (800) 360-6642, and ask for an RMA.  

 

 

Step 2:  Module Set Up 

Before installation into a chassis or enclosure, you must verify the application in which the L357 
will be used, i.e. 10Mbps, 100Mbps or 1000Mbps Ethernet, managed or non-managed etc.  The 
application may require setting the dip switches located at the rear of the L357.  If the unit is to be 
installed in the UCS 1030 enclosure, set the L357 to the desired configuration using Table 1 as a 
reference.  Otherwise, the L357 can be configured through software to the desired configuration 
when installed in the UCS 1000, 1001, 1002 or 1020.   
 

                

       

Figure 1.  L357 Switches and Default Setting 

 

Summary of Contents for L357 ESU

Page 1: ...E Parts List 1 x L357 xxxx 1 x UCS 1000 or UCS 1002 chassis 1 x UCS 1001 chassis 1 x UCS 1230 BAM Bus Access Module 1 x Model 1020 xxxx management access CPE or 1030 xxxx unmanaged CPE 1 x EIA 232 ser...

Page 2: ...n Several options for installation are available for the L357 For applications requiring multiple modules in the same location depending on the size and quantity requirements the UCS 1000 UCS 1001 or...

Page 3: ...ne 818 718 6300 FAX 818 718 6312 www canoga com P N 6942590 Rev A Page 3 of 8 Figure 2 L357 in UCS 1230 and UCS 1000 chassis Figure 3 L357 in UCS 1002 chassis Figure 4 L357 in UCS 1230 and UCS 1001 ch...

Page 4: ...he STA LED will light up red SPD amber and FDX green after the boot up process All other LEDs on the module are off Step 5 Management Access To access the user interface of the L357 a VT100 session mu...

Page 5: ...200bps Data bits 8 Parity None Stop bits 1 Flow control None Terminal emulation VT100 If the HyperTerminal screen is scrolling up make sure that Terminal Emulation in the Properties menu is set to VT1...

Page 6: ...stics 6 System Log 7 Utilities 8 Software Upgrade 9 Change Password 10 Manage Logged In Users 11 Logout Select 1 11 Messages Alarm Outputs None Figure 10 Main Menu screen Step 6 Module Configuration F...

Page 7: ...Loss Echo Disabled 6 Link Loss Fwd Disabled Select 1 6 Messages Alarm Outputs None Figure 11 Functional Configuration screen Step 7 Cable Connection Once the changes are made to the modules the UTP Un...

Page 8: ...tem Configuration screen Canoga Perkins Corp EdgeAccess Ethernet Media Converter 30 Nov 2005 Model L357 1564 V02 00 F19 Standalone 09 35 14 IP SNMP AGENT CONFIGURATION Local Remote Offline MAC Address...

Reviews: