9145E Network Interface Device

User Manual

Summary of Contents for EDGEACEESS 9145E

Page 1: ...9145E Network Interface Device User Manual...

Page 2: ...ormation in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the document is error free or that it is accurate with regard to...

Page 3: ...une longueur d onde 1300 de nm nm 1600 Utilisation des instruments optiques par exemple la collimation du syst me optique avec ce produit peut augmenter le danger L utilisation des commandes ou des a...

Page 4: ...t power supplies must have both power supply cords disconnected before servicing Wiring methods used for the connection of the equipment to the AC or DC MAINS SUPPLY shall be in accordance with the Na...

Page 5: ...remove any paint or non conductive coatings and establish a metal to metal contact Any paint or other nonconductive coatings should be removed on the surfaces between the mounting hardware and the enc...

Page 6: ...replacement cannot be performed in the field Call Canoga Perkins for an RMA number to arrange a repair Emissions and Immunity This device complies with part 15 of the FCC rules Operation is subject to...

Page 7: ...the fuse parts of the equipment that remain energized might represent a hazard during servicing Waste Electrical and Electronic Equipment WEEE Product Disposal Information Do not dispose of this prod...

Page 8: ...8...

Page 9: ...Power Requirements 14 Regulatory Compliance 14 Hardened 9145E Specifications 15 Physical Characteristics 15 Environmental Characteristics 15 Power Requirements 15 Regulatory Compliance 15 Mounting Opt...

Page 10: ...2 Redundant DC Power Base Unit 23 AC DC Power Base Unit 23 LED Indicators 23 Management Section LEDs 24 Data Interface Section LEDs 25 Chapter 3 Installation 27 9145E Installation Procedures 27 Unpack...

Page 11: ...1 Chapter 5 Troubleshooting 43 Optical Power Loss 43 Fault Conditions 43 Remote Fault RMTF 43 Link Loss Forwarding 45 Running Diagnostics 46 PING Testing 46 Latency and Jitter Testing 46 Loopback Diag...

Page 12: ...12...

Page 13: ...the Standard and Enhanced NIDS used in Central Office and Customer Premise Equipment locations an Extended Temperature hardened NID is also available for use in Outside Plant locations The 9145E Exten...

Page 14: ...l Characteristics Operating Temperature 0 to 50 C Operating Humidity 0 to 90 Relative Humidity non condensing 1 2 3 Power Requirements 100 VAC to 240 VAC auto ranging 50 60 Hz 0 5 Amps 48VDC 36 to 72V...

Page 15: ...1 3 3 Power Requirements 48VDC 36 to 72VDC 1 Amp 24VDC 18 to 36VDC 2 Amps 1 3 4 Regulatory Compliance EN60825 1 laser safety CE Mark EMC Directive EN55022 Class A EN 55024 EN 61000 3 2 3 3 ETL cETL L...

Page 16: ...e brackets required see Figure 1 2 for their particular rack installation Figure 1 1 9145E Mounting Brackets 1 4 2 Wall Mounting Canoga Perkins includes a mounting template in the shipping container s...

Page 17: ...9145e 4 Port Advanced Model Redundant AC Power 9145E 101 3 0 9145e 4 Port Advanced Model Redundant DC Power 9145E 101 4 0 9145e 4 Port Advanced Model Redundant AC DC Power 9145E 104 0 0 9145e 2 Port...

Page 18: ...Hardened V1 Engine UTP SFP User Port UTP SFP Network Port Local Ethernet UTP Management Port Single 48VDC Power Supply Integral Fans 9145E 303 3 0 Hardened V1 Engine UTP SFP User Port UTP SFP Network...

Page 19: ...s to choose from see Figure 2 2 Five options are offered 1 Single AC Power 2 Redundant AC Power 3 Single DC Power 4 Redundant DC Power 5 Redundant AC and DC power Figure 2 2 9145E Rear Panel The Stand...

Page 20: ...tions UTP connectors support both full duplex and half duplex operation in 10 100 1000 Mbps mode SFP connectors support full duplex operation at 10 1000 Mbps 2 4 Management Ports 2 4 1 EIA 232 Console...

Page 21: ...d SFP connectors present by default the UTP is the Active Connector it can currently transmit and receive data while the SFP is the Inactive Connector i e it currently cannot transmit or receive data...

Page 22: ...with the unit Figure 2 4 Single AC Power 2 6 3 Redundant AC Power Base Unit The Redundant AC powered 9145E base unit see Figure 2 5 has two power connectors on the rear panel Appropriate AC power cor...

Page 23: ...t see Figure 2 8 has two power interfaces on the rear panel one that supports DC power input and one that supports an AC power input An appropriate AC power cord and a DC terminal block are supplied w...

Page 24: ...n tion such as the failure of one of the redundant power supplies temperature or voltage out of range alarm or a fan failure POWER Off Power is off Green Power is on Amber System is booting One power...

Page 25: ...n 1000BaseT Amber 100BaseTX System Test Red Remote Fault SFP Only Blinking Red Invalid Unsupported SFP installed SFP Only Slow Blinking Green Connector Selected with No Link LNK ACT Off No link No tra...

Page 26: ...Functional Description 9145E Ethernet Network Interface Device User Manual LEDIndicators 26...

Page 27: ...rational In the event that the unit needs to be returned contact Canoga Perkins Customer Service for a Return Authorization Number RMA and instructions for return shipment CAUTION Follow electrostatic...

Page 28: ...in either a 19 rack or a 23 rack and two 9145Es can be mounted side by side in either a 19 rack or a 23 rack Rack mounting kits see Table 3 1 are available for each of the four rack mounting possibili...

Page 29: ...al Unit 1802 2019 Bracket rack mount dual 19 6213614 219 2 Screw flat head 8 32 x 0 25 80680041 4 Bracket rack mount center 6213615 2 Strap rack mount center 6213616 1 Bracket rack mount dual rear 621...

Page 30: ...rackets attach to the two threaded holes on each side of the 9145E toward the front see Figure 3 3 using the flat head screws provided Torque the flat head screws to 14 5 15 5 in lb Figure 3 3 Install...

Page 31: ...ver the front of each center bracket see Figure 3 5 The rear center bracket is attached to the threaded holes at the top inside corner of the back of each 9145E see Figure 3 6 2 Place unit with bracke...

Page 32: ...o the right or to the left see Figure 3 8 Figure 3 8 Wall Mounting Cutout Locations Assure that there is enough unobstructed space around the perimeter of the 9145E to allow for adequate airflow and s...

Page 33: ...ventilation Canoga Perkins recommends a space of 3 to 5 inches be left unobstructed to allow for SFP module access cable access and power connections To install the 9145E on a flat surface place the 9...

Page 34: ...vailable port and push firmly to seat the module see Figure 3 10 3 Raise latch to lock module in place Figure 3 10 SFP Modules 3 5 Connecting the Electrical Power NOTE When power is applied all LED in...

Page 35: ...ollowing is the recommended procedure to connect the 9145E to a DC power source Use 18ga to 12ga wire for GND VDC and VDC connections 1 Unplug the terminal block from the 9145E 2 Turn off the DC power...

Page 36: ...l 3A slow blow fuse Although not required an external fuse can be used to isolate the 9145E in a shared fuse distribution panel Based on the 9145E inrush power characteristics the minimum fuse ratings...

Page 37: ...enly 3 Insert exposed wire into the grounding lug until it bottoms out inside the barrel 4 Position the crimping tool over the center of the grounding lug with the lug in the crimping tool s proper cr...

Page 38: ...n installing or removing cables Connect the Optical Fiber cables to the SFP modules as follows 1 Plug in the optical cables with proper Tx to Rx or Rx to Tx orientation The optical cables must use LC...

Page 39: ...screens see the 9145E NID Software User Manual Figure 4 1 9145E Status Indicators 4 1 1 Power and Status LEDs The power PWR and status STA LEDs located to the right of the console port see Figure 4 1...

Page 40: ...ature or voltage out of range alarm or a fan failure POWER Off Power is off Green Power is on Amber System is booting or one power supply failed in a redundant power supply configuration Red One of th...

Page 41: ...SNMP V1 V2C V3 4 2 1 Setting Up the VT 100 Terminal When using the console port you can use the HyperTerminal Emulation program that is included with Microsoft Windows operating systems The Telnet ses...

Page 42: ...ect an icon to identify this connection on your desktop and click OK The Connect To window will open 3 Select COM from the Connect using drop down menu and click OK The Com1 Properties window will ope...

Page 43: ...al information about fault conditions appears on the System Alarms Log Use the System Alarms Screen to view alarms and faults on the 9145E see the 9145E NID Software User Manual 5 2 1 Remote Fault RMT...

Page 44: ...or voltage out of range alarm or a fan failure POWER Off Power is off Green Power is on Amber System is booting or one power supply failed in a redundant power supply configuration Red One of the boar...

Page 45: ...tware User Manual LED Name State Condition SPD Off 10BaseT Auto Connector Not Selected Green 1000BaseT Amber 100BaseTX System Test Red Remote Fault SFP Only Blinking Red Invalid Unsupported SFP instal...

Page 46: ...see the 9145E Ethernet NID Software User Manual 5 4 Loopback Diagnostics Use Loopbacks to diagnose a fault on the optical link The 9145E supports two loopback modes that you can set at the local site...

Page 47: ...initiate loopbacks configure address swapping and CRC recalculation options and to run a loopback test see the 9145E NID Software User Manual 5 4 1 User Mode User Mode loops data received on the loca...

Page 48: ...ork Port Tx Data is not sent out the local User Port Tx and incoming data on the local User Port Rx is ignored see Figure 5 4 To set this mode set the Loopback State for the Remote module to Remote se...

Page 49: ...up To ensure proper performance levels measure Transmitter Output Power Receiver Input Power and attenuation on all fiber links Each 9145E is shipped with a document that lists the output power for ea...

Page 50: ...ical power meter to the end of the transmit fiber at the local site 6 Measure and record the optical power on the transmit fiber at the local site This is the receiver input power for the transmit fib...

Page 51: ...E and the local device Each fiber connection can generate 0 5 dB of additional loss NOTE If you cannot determine the Rx sensitivity contact Canoga Perkins Technical Support for assistance Follow these...

Page 52: ......

Page 53: ......

Page 54: ...CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth California 91311 6008 USA Phone 818 718 6300 FAX 818 718 6312 Web Site www canoga com Email fiber canoga com...