44
4. Memory / Bluetooth Mode
2. A-303 , A302 Dongle ,Spp-A303PT
Mac address configuration, total of 12 digits, Please refer to the HEX ASCII
table (From 0~9, A~F).
Configuration
Max. Configurable Length
Default Setting
Hexadecimal /
decimal
barcode table
12 digits
000000000000
Procedure:
(1) Enter: (Enter setting)
*/$%ENTR*
(2) “DongleBtMacAddr”
*B28FE*
(3) Scan Hexadecimal/Decimal Barcode table for input parameters.
(4) OK : (Selection confirmed)
*%OK*
(5) End: (Exit setting)
*ZEND*
Example:
Set Remote Mac Address to 00126F006EAA
A. Scan “Enter” barcode
B. Scan “DongleBtMacAddr” barcode
C. Scan parameters from Hexadecimal /decimal barcode table =>“0”, “0”,
“1”,”2”, “6”,”F”, “0”,”0”, “6”,”E”, “A”,”A”
”OK” (Set “Remote Mac Address
“ value to
00126F006EAA
)
D. Scan “End” barcode
Note:
If scanner connection mode is “A-303 Dongle” or “A-302 Dongle” or
“Spp-A303PT” mode, configuration of Mac address does required, and the
configuration cannot be “000000000000”