05 GB
For any questions regarding power supply cord refer to After Sales
Service or a qualified technician.
Before making the connection, make sure that the installation is
protected by a suitable fuse, and that it is fitted with wires of a large
enough section to supply the appliance normally.
To proceed to the new connection, please follow below instructions:
It is however possible to connect the hob to:
"Installation must conform to the standards & directives."
Manufacturer declines all responsibility for any damage that
might be caused by unsuitable or unreasonable use.
WARNING: Manufacturer cannot be held responsible for any incident
or its consequences that may arise during the use of an appliance not
linked to the earth, or linked to an earth whose continuity is defective.
Before any electrical operation, please check the supply tension
shown on the electricity meter, the adjustment of the circuit- breaker,
the continuity of the connection to earth to the installation and that the
fuse is suitable.
The electrical connection to the installation should be made according
to the rated power of the Appliance; this should be made via an Omni
pole cut-out switch.
The yellow/green wire of the power supply cable must be connected to
the earth of both power supply and appliance terminals.
If the appliance has a socket outlet, it must be installed so that the
socket outlet is accessible.
If the hob is fitted with power supply cord, this shall be connected only
to a power supply of 220-240 V between phase and neutral.
Three Phase 220-240 V3
Three Phase 380-415 V2N
2
3
1
Open the cover n the follow ng sequence:
Turn over the hob, glass s de aga nst the work ng top, tak ng care to
protect the glass.
If it should be necessary to replace the power supply cord, connect the
wire in accordance with following colors/codes:
ATTENTION:
SHUNT
- put the blade of a flat screw-dr ver n front of each tab "2" e
"3", push n and press;
To release the power supply cord:
Operat ons to be carr ed out to make a new connect on:
- Pass the power supply cable nto the clamp;
- unscrew the cable clamp "1";
- f nd the two tabs located on the s des;
- Remove the screws reta n ng the term nal block wh ch
conta ns the shunt bars and the conductors of the supply cord;
- remove the cover.
- Pull out the supply cord.
- Choose the power supply cable n accordance w th the
recommendat ons n the table;
- Accord ng to the nstallat on and w th the
help of shunt bars wh ch you should have
recovered n the f rst operat on, f x the
conductor as shown on the chart;
- Screw the cable clamp.
- F x the cover;
- Str p the end of each conductor of the
supply cord on a 10 mm length, by tak ng n
account the requested length of the cord for
the connect on to the term nal block;
Connection to the terminals on the terminal block
LAY OUT
"1-6"
LAY OUT
"7"
MONOPHASE or TWO PHASES 220-240 V
~
Cable
HO5V2V2F
Cable
HO5V2V2F
Cable
HO5V2V2F
2
3x2,5 mm
2
3x4 mm
2
4x1,5 mm
2
4x1,5 mm
2
4x1,5 mm
2
4x1,5 mm
THREE PHASES 220-240 V
3~
THREE PHASES 380-415 V
2N~
N
=
Neutr
al
PE
=
Earth
L1 / L2 / L3 =
Phase
220-240V 3 ~
PE
L1
L2
L3
380-415V 2N ~
N
PE
L1
L2
L3
PE
L1
L2
220-240V ~
N
L
220-240V 2 ~
L2
PE
L1
PE