background image

 

vi 

LIST OF FIGURES 

 
Figure 1.  M-MODULE Installation ............................................................................................ 5 
Figure 2.  M220 Functional Block Diagram................................................................................. 7 
Figure 3.  M220 Switching Schematic ......................................................................................... 9 
Figure 4.  Jumper Positions ....................................................................................................... 10 
Figure 5.  I/O Registers ............................................................................................................. 12 
 
Figure A-1. Front Panel I/O Signals......................................................................................... A-1 
 

LIST OF TABLES 

 

Table I.  Specifications ................................................................................................................ 2 
Table II.  I/O Address Map/Command Summary....................................................................... 11 
Table III.  M/MA Module PROM IDENT Words...................................................................... 14 

Table IV.  Matrix Drive

.......................................................................................................... 16 

 

 
 

C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas  78681 <> www.chtech.com

Summary of Contents for M 2 2 0

Page 1: ...0 F O R M E R L Y H P E 2 2 7 2 A U S E R S M A N U A L D U A L 8 X 1 M U L T I P L E X E R M M O D U L E Document Part No 11029554 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 7868...

Page 2: ...Hewlett Packard Agilent User Manual s with their expressed written permission The information and or drawings set forth in this document and all rights in and to inventions disclosed herein which mig...

Page 3: ...mendments to the manual If any amendments are provided for this manual they are printed on colored paper and will be provided with the module and manual Manual updates may also be found on out web sit...

Page 4: ...ailable in many formats such as Ethernet VME VXI PXI cPCI and the PC Contained within this manual are the physical and electrical specifications installation and startup procedures functional descript...

Page 5: ...RESHIPMENT 6 3 0 FUNCTIONAL DESCRIPTION 7 3 1 OVERVIEW 7 3 1 1 M Module Interface 7 3 1 2 Module Control 7 3 1 3 ID EEPROM 8 3 1 4 Row and Column Drivers 8 3 1 5 Driver Power Switch 8 3 2 IDENTIFICAT...

Page 6: ...Figure 4 Jumper Positions 10 Figure 5 I O Registers 12 Figure A 1 Front Panel I O Signals A 1 LIST OF TABLES Table I Specifications 2 Table II I O Address Map Command Summary 11 Table III M MA Module...

Page 7: ...between test points instrumentation factory automation and test fixtures CAUTION This module uses latching relays that retain their last programmed state whenever power is removed closed relays will r...

Page 8: ...A A peak A A peak Power Per Switch DC Per Switch AC 16 to 1 Per Module DC 16 to 1 Per Module AC 8 to 1 Per Module DC 8 to 1 Per Module AC 50 50 50 50 100 100 W VA W VA W VA Thermal Offset 3 typ V RESI...

Page 9: ...A not supported Triggers not supported Identification IDENT Manufacturer ID 0FFF16 See note below Model Number 068816 VXI Model Number 025D16 Note C H obtained the manufacturing rights from Hewlett Pa...

Page 10: ...4 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...

Page 11: ...static controlled workstation whenever possible At a minimum avoid work areas that are potential static sources such as carpeted areas Avoid unnecessary contact with the components on the module 2 3 I...

Page 12: ...ling the bag keep trapped air volume to a minimum The shipping container should be a rigid box of sufficient size and strength to protect the equipment from damage If the module was received separatel...

Page 13: ...ntrol VCC DGND RST ROM ID EEPROM Figure 2 M220 Functional Block Diagram 3 1 1 M Module Interface The M Module Interface allows communication between the M220 and the carrier module The interface is an...

Page 14: ...rom Module Control into the bipolar buffered drive signals COL_DR 4 1 The COL_DR 4 1 signals provide either current source from the 5VDR supply relay reset or current sink to ground relay set 3 1 5 Dr...

Page 15: ...CH13_HI 14 CH13_LO 30 CH14_HI 44 CH14_LO 43 CH15_HI 42 CH15_LO 8 MUXB_HI_COM 24 MUXB_LO_COM Channel 8 Channel 9 Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 0 Channel 1 Ch...

Page 16: ...jumper connecting all pins the module is configured as a single 16 to 1 multiplexer The M220 leaves the factory with the jumper placed in position A dual 8 to 1 multiplexer If you need to change this...

Page 17: ...gister Y N 00h Status Register Read Only N 02h Control Register Read Write N 04h 0Eh Reserved NA N 10h Row 0 Set Register Read Write Y 12h Row 0 Reset Register Read Write Y 14h Row 1 Set Register Read...

Page 18: ...iguration of the jumper Reg 02 Control Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write Reserved TM DPE STE INTE RST Read Reserved TM DPE STE INTE RST TM Timer Mode proper operation is guaranteed only...

Page 19: ...1 R2C0 Reg 1C Row 3 Set Register Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write Unused R3C3 R3C2 R3C1 R3C0 Read Unused R3C3 R3C2 R3C1 R3C0 Reg 1E Row 1 Reset Register Bit 15 14 13 12 11 10 9 8 7 6 5...

Page 20: ...Number 1 0002 3 Module Characteristics 2 0868 4 7 Reserved 0000 8 15 M Module Specific 0000 16 VXI Sync Code ACBA 17 VXI ID 0FFF 3 18 VXI Device Type 3 F25D M220 19 31 Reserved 0000 32 63 M Module Sp...

Page 21: ...FIFO see note below then the module asserts an interrupt only after the completion of the fourth operation Note The module asserts an interrupt after the relay drive time is complete relay drive time...

Page 22: ...To guarantee break before make relay operation write to the Row n Reset registers before writing to the Row n Set registers 2 It is important to use the FIFO status bits when writing to the Row n Set...

Page 23: ...s an interrupt only after the completion of the fourth operation Note The module asserts an interrupt after the relay drive time is complete relay drive timer and no other operations have been stored...

Page 24: ...18 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...

Page 25: ...non inductive that may be applied to the M220 is Per Switch 2 ADC 2 AAC peak Per Module 8 ADC 8 AAC peak Pin Use Pin Use Pin Use 1 CH0_HI 16 CH3_HI 31 CH3_LO 2 CH0_LO 17 CH2_HI 32 CH2_LO 3 CH7_LO 18...

Page 26: ...A 2 C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...

Page 27: ...N O T E S C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...

Page 28: ...C H Technologies Inc 445 Round Rock West Drive Round Rock Texas 78681 www chtech com...

Page 29: ...oever You may of course continue to use the information which you supply Please refrain from using this form for technical questions or for requests for additional publications this will only delay th...

Page 30: ...r or not your comments were being incorporated NOTE This form may not be used to request copies of documents or to request waivers deviations or clarification of specification requirements on current...

Reviews: