CANARMNA CEP80 Quick Start Manual Download Page 1

WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

Cod

0060302208

Model

CEP80

WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:

VENTILATION FANS

CEP110 CEP150 

Use an on/off switch to operate this fan.

See “CONNECT ELECTRICAL WIRING” for details.

www.canarmna.com

CANARMNA

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the 

dusting brush attachment.The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive 

or unusual noises, replace the motor with the exact service motor. The impeller should also be replaced.

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power 

from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent 

warning device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and 

standards, including fire-rated construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to 

prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by 

the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning   

Engineers (ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f ). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit 

(ceiling installation only). 

h). This unit must be grounded. 

 i). Not for Use in Kitchens.

 j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or 

ceilings or into attics, crawl spaces, or garages.

k). 

WARNING: 

To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.

 l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. 

    

DO NOT MOUNT THIS PRODUCT IN A WALL. 

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 

4. Please read specification label on product for further information and requirements. 

   *The manual in electronic format can be download in our company web, or obtained from our dealer.