6 Installation
7
/
32
0~15°
FIG.6-5 Installation Angle Requirements
13) Do not install the inverter outdoors in salt, sulfur or other corrosive areas.
The inverter would be corroded in salt area (i.e. marine environments), and the corrosion may cause fire. Salt area refers
to the region within 500 meters from the coast.
Please consult the CSI Solar Co., Ltd. technical support department on the use of inverters in special climates (i.e. salt,
sulfur, or ammonia areas) which may affect the product warranty.
14) Need two persons to install the inverter.
6.2 Mounting Wall-mounting Bracket
Danger
To avoid electrical shock or other injury, please inspect existing electronic or plumbing installations
before drilling holes.
Procedure:
1) Use the wall-mounting bracket as a template and mark the positions of the drill holes, then drill the 4 holes
accordingly, as per FIG. 6-6. (Diameter = 11mm, Depth ≥ 55mm).
Note: The external dimensions (W × H) of inverter are shown as a dashed line in FIG. 6-6.
237
45
164
74.5
250
FIG.6-6 Drilling Positions (W x H, 399 x 446mm)
2) Drill expansion anchors into the corresponding four holes, and then fix the wall-mounting bracket to the wall with
self-tapping screws (spec, ST 6.3 x 50), as per FIG. 6-7 & FIG. 6-8.
FIG.6-7 Install Expansion Anchors FIG.6-8 Fix Wall-mounting Bracket