Testing the temperature controller
20
Check for 120 volts on the orange wire terminal
#6
on the
temperature controller.
✓
If 120 volts is NOT present,
the temperature controller
is defective.
✓
If voltage is present, the 150F thermal limit disc is
defective or the thermal heat thermostat in the fan
➢
NOTE:
If the display on the temperature controller is
reading 000 (or other false reading), the thermocouple
Is defective.