![Campbell SkyVUE 8 Product Manual Download Page 66](http://html1.mh-extra.com/html/campbell/skyvue-8/skyvue-8_product-manual_3808856066.webp)
Description of the least significant alarm word (right side, bits going left to right)
Bit
Description
XXXX XXXX 8000
Photo diode temperature is out of range
XXXX XXXX 4000
Photo diode is saturated
XXXX XXXX 2000
Photo diode calibrator temperature is out of range
XXXX XXXX 1000
Photo diode calibrator has failed
XXXX XXXX 0800
The sensor could not reach the desired gain levels
XXXX XXXX 0400
Laser run time has been exceeded
XXXX XXXX 0200
Laser temperature out of range
XXXX XXXX 0100
Laser thermistor failure
XXXX XXXX 0080
Laser is obscured. This can only be set if the laser is on
XXXX XXXX 0040
Laser did not achieve significant output power
XXXX XXXX 0020
Laser max power exceeded
XXXX XXXX 0010
Laser max drive current exceeded
XXXX XXXX 0008
Laser power monitor temperature out of range
XXXX XXXX 0004
Laser power monitor test fail
XXXX XXXX 0002
Laser shutdown by top board
XXXX XXXX 0001
Laser is off
5.1.8 Message polling
The
POLL Sensor_ID Message_ID
command requests the
Message_ID
from the
Sensor_ID
. Where
Message_ID
is a SkyVUE 8 message type as defined in
The following example uses the SkyVUE 8
POLL
command to request preconfigured message
outputs.
First configure the SkyVUE 8 to use polling mode from the terminal interface via the
MCFG
command as follows:
CS136>
MCFG 0
0 1 0 0 0 0