
Table 8-3: Identify commands for the RainVUE-series
Type of command
Command
Sensor response
Comment
Identify
measurement
parameter 001 of
M
command
a
IM_001!
aAdjRain,Inches
or
aAdjRain,mm
AdjRain: adjusted or
intensity-corrected
precipitation since last
measurement
Units: inches or mm
Identify
measurement
parameter 002 of
M
command
a
IM_002!
aRawTips,Tips
RawTips: number of raw
bucket tips since last
measurement (counts)
Units: counts
Identify
measurement
parameter 003 of
M
command
a
IM_003!
aTotAdjRain,Inches
or
aTotAdjRain,mm
TotAdjRain: total
adjusted or total
intensity-corrected
precipitation since last
reset
Units: inches or mm
Identify
measurement
parameter 004 of
M
command
a
IM_004!
aAvgInt,Inches/Hour
or
aAvgInt,mm/Hour
AvgInt: average
precipitation intensity
since last measurement
Units: inches/hour or
mm/hour
Identify
measurement
parameter 005 of
M
command
a
IM_005!
aMaxInt,Inches/Hour
or
aMaxInt,mm/Hour
MaxInt: maximum peak
precipitation intensity
since last measurement
Units: inches/hour or
mm/hour
8.4 Calculations
Reported measurement values in the measurement commands (
M
,
MC
,
C
,
CC
,
R0
,
RC0
, or
R9
) are
as follows:
1. Intensity Correct Accumulation (ICA) since last measurement accumulator reset
1
(inches)
2. Number of tips since last measurement accumulator reset
1
RainVUE-Series SDI-12 Precipitation Sensors
21