Appendix G. Generic Modbus® Control
G-3
Modbus Packet Example 3: Set "SampPerBottle" Registers = 24.0 (0x 41 C0
00 00)
TX: 01 10 00 02 00 00 41 C0 {CRC}
RX: 01 10 00 02 00 02 {CRC}
Modbus Packet Example 3: Set "SampPerBottle" Registers = 24.0 (0x 41 C0
00 00)
TX: 01 10 00 02 00 00 41 C0 {CRC}
RX: 01 10 00 02 00 02 {CRC}
Modbus Packet Example 4: Get "Bottle", "Sample", "Response", and "Batt"
Registers
TX: 01 04 00 16 00 08 {CRC}
RX: 01 04 10 00003F80 00003F80 00000000 00004148 {CRC}