PVS5120-Series Portable Samplers
14
FIGURE 6-6. Advanced Sampler Settings tab
•
Set Final Purge Time:
Allows the
Final Purge Time
to be set
independently from the
Purge Time
.
•
Final Purge Time:
Specifies the amount of time the sampler hose is
evacuated after a sample is collected. The minimum value is 0 s. The
maximum value for SDI-12 control is 280 s. The maximum value for
PakBus®, Pulse, Modbus®, and Time control types is 800 s. The
setting is only active if the
Set Final Purge Time
is toggled to
set
.
•
Sample Volume Level Set Time:
The amount of time the sample is
evacuated out of the metering chamber back into the intake hose to
reach the desired volume. The sample volume is determined by the
level of the volume set rod. The minimum time is 3 s. The maximum
time for the SDI-12 control type is 30 s. The maximum time is 800 s
for PakBus®, Pulse, Modbus®, and Time control types. The Auto
Deploy routine sets this to 12 s.
•
Sample Deposit Time:
The amount of time the sampler waits for the
sample volume to drain into the sample bottle. Minimum time is 5 s.
The maximum time for SDI-12 is 20 s. The maximum time for
PakBus®, Pulse, Modbus®, and Time control types is 800 s. If the
sample volume is greater than 420 mL, the deposit time must be 18 to
20 s. The Auto Deploy routine sets this to 8 s.
•
Set Vacuum Time Out:
Allows the user to choose the default (two
times the Purge Time) or to independently set the time out. If the
default is chosen and the Purge Time is 0 s, the time out value is 10 s.
This is not set during Auto Deploy.
•
Vacuum Time Out:
The maximum time-out for SDI-12 control type
is 330 s. The maximum vacuum time-out for PakBus®, Pulse,
Modbus®, and Time control types is 800 s.
Summary of Contents for PVS5120 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 70: ...Appendix A Sample Transport Velocity A 2...
Page 78: ...Appendix B Example Programs B 8...
Page 86: ...Appendix C Monitoring Sampler Status via RS 485 C 8...
Page 96: ...Appendix G Generic Modbus Control G 4...
Page 100: ...Appendix H ISO5667 Conformity H 4...
Page 101: ......