Campbell Scientific typically advises against frequent routine setting of the
datalogger’s clock. Setting the clock could result in data with duplicate or
missing timestamps, especially if data is being saved in final storage fairly
quickly. For instance, assume you are storing 1-minute data. If the datalogger’s
clock reaches 11:45 and it stores data for that period, and then you set the clock
using an Allegro CE whose internal clock reads 11:44, you will end up with
two different arrays of data with a timestamp of 11:45.
Flags/Ports
The datalogger’s ports and flags can be viewed and toggled from the
Flags/Ports tab. All of the flags and ports in the datalogger are displayed on the
screen. If a flag or port is High, a check mark will appear in the box beside the
port or flag. If a flag or port is low, the box will be empty.
To change the state of a port or flag, touch the box for that port or flag. There
may be a small time lag between when the box is touched and when the state of
the port or flag appears to change.