FIGURE 8-2. Bridge mode LoggerNet setup
8.2.2.5 Connect
You are now ready to connect to the data logger using the
LoggerNet
Connect screen.
8.2.3 TCP serial server
The NL241 can tunnel RS-232 and CS I/O serial communications over Wi-Fi. Any packet sent to
the configured IP port will have the IP layer removed, the data is then directed to the serial
connection.
8.2.3.1 Physical setup
Using the supplied serial cable, connect the NL241 CS I/O port or RS-232 port to the data logger
CS I/O or RS-232 port, respectively. The NL241 will be powered if connected via CS I/O.
Alternatively, power the NL241 through the barrel-connector jack located on the edge of the
device. Connect the NL241 to your local wireless network by attaching an antenna to the NL241
Antenna connector. Ensure that the device is powered up by inspecting the LED.
NL241 Wireless Network Link Interface
30