WARRANTY AND ASSISTANCE

 

 
 
This equipment

 

is warranted by CAMPBELL SCIENTIFIC (CANADA) CORP. (“CSC”) to 

be free from defects in materials and workmanship under normal use and service for 

twelve (12) months

 from date of shipment unless specified otherwise.  

***** Batteries 

are not warranted. *****

 CSC's obligation under this warranty is limited to repairing or 

replacing (at CSC's option) defective products.  The customer shall assume all costs of 
removing, reinstalling, and shipping defective products to CSC.  CSC will return such 
products by surface carrier prepaid.  This warranty shall not apply to any CSC products 
which have been subjected to modification, misuse, neglect, accidents of nature, or 
shipping damage. This warranty is in lieu of all other warranties, expressed or implied, 
including warranties of merchantability or fitness for a particular purpose.  CSC is not 
liable for special, indirect, incidental, or consequential damages. 
 
Products may not be returned without prior authorization.  To obtain a Return 
Merchandise Authorization (RMA), contact CAMPBELL SCIENTIFIC (CANADA) CORP., 
at (780) 454-2505.  An RMA number will be issued in order to facilitate Repair Personnel 
in identifying an instrument upon arrival.  Please write this number clearly on the outside 
of the shipping container.  Include description of symptoms and all pertinent details. 
 
CAMPBELL SCIENTIFIC (CANADA) CORP. does not accept collect calls. 
 
Non-warranty products returned for repair should be accompanied by a purchase order to 
cover repair costs. 
 
 
 
 
 
 
 
 

 

 
 

Summary of Contents for MMW-005

Page 1: ...INSTRUCTION MANUAL Copyright 2008 Campbell Scientific Canada Corp MMW 005 Solid State Wind Sensor Dec 2010...

Page 2: ...glect accidents of nature or shipping damage This warranty is in lieu of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CSC is no...

Page 3: ...ications 3 4 Installation 4 5 Wiring 6 5 1 Output String According to NMEA 0183 7 6 CR1000 Example Program 7 7 Maintenance 9 TABLE OF FIGURES Figure 1 MMW 005 Sensor Mounting Base 2 Figure 2 Integrate...

Page 4: ...ip to measure wind speed and wind direction based on the temperature differences across the chip surface These temperature differences are processed by a small microprocessor in the sensor resulting i...

Page 5: ...speed and direction Guide discs along the top and bottom of the sensor ensure that wind passes through the sensor in the correct manner Mathematical processing by the microprocessor and signal conditi...

Page 6: ...0183 protocol serial Baud rate 4800 Data bits 8 Stop bits 1 Parity none 4 Installation The MMW 005 is mounted to either a horizontal or vertical pipe with the use of the C2410 Mounting Bracket Figure...

Page 7: ...racket It is recommended to leave the sensor cable in place as it can slide into the notch provided at the tip of the bracket Figure 5 Mounting Base Attached Before reattaching the MMW 005 to the moun...

Page 8: ...need to push the sensor into the base until it is completely secured Figure 7 Figure 7 MMW 005 Mounted The MMW 005 and C2410 can now be mounted to the intended pipe using the provided v bolt and hard...

Page 9: ...eather Instruments MWV Wind speed and direction ddd Wind direction value 0 359 R Relative to the vessel not applicable ss s Wind speed value 0 25 5 m s M Unit for wind speed m s A Data always valid fo...

Page 10: ...Mean_Horizontal_Wnd_Spd Unit_Vector_Mean_Wnd_Dir Standard_Deviation_Wnd_Dir EndTable DataTable Wnd10Min True 1 DataInterval 0 10 Min 10 10 minute average of WindDir and WindSpeed WindVector 1 Wind_Sp...

Page 11: ..._________________________________________________________ NextScan EndProg 7 Maintenance The wind sensor has no moving parts and requires no other maintenance than the cleaning of the sensor itself Th...

Reviews: