11.4 Replacing an HS2P Sensor
1.
Unplug the cable that attaches the sensor to the display.
2.
Remove the plastic bumper.
3.
Use the wrench to remove the hex bolts and nuts that secure the sensor to
the pole.
4.
Use Phillips screwdriver to remove the screws and tabs that fasten the
cable to the pole.
5.
Remove the old sensor.
6.
Place the new sensor in the slots at the bottom of the pole.
7.
Secure the sensor to the pole using the hex bolts and nuts.
Do not over tighten the hex bolts.
8.
Put on the plastic bumper.
9.
Secure the sensor cable to the pole using the Phillips screws and tabs.
10.
Connect the cable to the display.