background image

Assistance 

Products may not be returned without prior authorization.  The following 
contact information is for US and international customers residing in countries 
served by Campbell Scientific, Inc. directly.  Affiliate companies handle 
repairs for customers within their territories.  Please visit 

www.campbellsci.com

 to determine which Campbell Scientific company serves 

your country. 

To obtain a Returned Materials Authorization (RMA), contact CAMPBELL 
SCIENTIFIC, INC., phone (435) 227-9000.  After an applications engineer 
determines the nature of the problem, an RMA number will be issued.  Please 
write this number clearly on the outside of the shipping container.  Campbell 
Scientific's shipping address is: 

CAMPBELL SCIENTIFIC, INC.

 

RMA#_____ 
815 West 1800 North 
Logan, Utah 84321-1784 

For all returns, the customer must fill out a "Statement of Product Cleanliness 
and Decontamination" form and comply with the requirements specified in it.  
The form is available from our web site at 

www.campbellsci.com/repair

.  A 

completed form must be either emailed to 

[email protected]

 or faxed to 

(435) 227-9106.  Campbell Scientific is unable to process any returns until we 
receive this form.  If the form is not received within three days of product 
receipt or is incomplete, the product will be returned to the customer at the 
customer's expense.  Campbell Scientific reserves the right to refuse service on 
products that were exposed to contaminants that may cause health or safety 
concerns for our employees. 

Summary of Contents for HFP01

Page 1: ...Model HFP01 Soil Heat Flux Plate Revision 7 12 C o p y r i g h t 2 0 0 2 2 0 1 2 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ......

Page 3: ...emoving reinstalling and shipping defective products to Campbell Campbell will return such products by surface carrier prepaid within the continental United States of America To all other locations Ca...

Page 4: ...g container Campbell Scientific s shipping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Clea...

Page 5: ...Wiring 5 6 3 Programming 5 6 4 Soil Heat Flux and Storage 7 7 Maintenance 8 8 References 8 Appendix A General Theory of Heat Flux Sensors A 1 A 1 General Theory A 1 A 2 Extended Theory A 2 Figures 6...

Page 6: ......

Page 7: ...hould be handled as a precision scientific instrument 3 Initial Inspection Upon receipt of the HFP01 inspect the packaging and contents for damage File damage claims with the shipping company The mode...

Page 8: ...he sensor as the HFP01 The sensor s cable can terminate in Pigtails that connect directly to a Campbell Scientific datalogger option PT Connector that attaches to a prewired enclosure option PW Refer...

Page 9: ...must be completely inserted into the soil face before the hole is backfilled FIGURE 6 1 Placement of heat flux plates 6 Installation 6 1 Placement in Soil The standard set of sensors for measuring soi...

Page 10: ...t the side with the red label is facing the sky and the side with a blue label facing the soil NOTE In order for the HFP01 to make quality soil heat flux measurements the plate must be in full contact...

Page 11: ...Shield Clear G 6 3 Programming To calculate the calibration multiplier divide 1000 by the nominal calibration sensitivity i e 1000 sensitivity The nominal calibration sensitivity is unique for each HF...

Page 12: ...P01 1 1000 sensitivity 1000 67 1 Const HFP01_CAL_2 14 92 Unique multiplier for HFP01 2 1000 sensitivity 1000 67 0 Variables Energy balance sensors Public shf 2 Dim shf_cal 2 Soil heat flux plate calib...

Page 13: ...n of CR23X Program using the Differential Measurement Instruction The instruction below does not store data in final storage P92 P77 and an output processing instruction are required to store the data...

Page 14: ...lk density and mass basis soil water content can be found by sampling Klute 1986 The volumetric soil water content is measured by the CS616 water content reflectometer A value of 840 J kg 1 K 1 for th...

Page 15: ...and the thermal conductivity of the sensor Using more thermocouples in series will enhance the output signal In Figure A 1 the joints of a copper constantan thermopile are alternatively placed on the...

Page 16: ...r of magnitude of this error for strongly different thermal conductivity values between the sensor and its environment for example 0 6 for a typical sensor and 0 03 for an insulating wall is about 40...

Page 17: ......

Page 18: ...ntific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller...

Reviews: