Model HC2S3 Temperature and Relative Humidity Probe
11
Tools required for installing an HC2S3 sensor in a radiation shield to a tripod
or tower include:
•
1/2 inch open-end wrench
•
small screwdriver provided with datalogger
•
UV-resistant cable ties
•
small pair of diagonal-cutting pliers
•
adjustable wrench with a minimum 1-7/8 inch jaw size
Attach the probe to the cable by aligning the keyed connectors, pushing the
connectors together, and tightening the knurled ring.
7.3.1 Installation in a 41003-5 10-Plate Shield
1.
The HC2S3 is shipped with an adapter to work with the 41003-5 10-plate
shield. Loosely thread the collar adapter into the base of the 10-plate
shield.
2.
Insert the HC2S3 sensor into the collar. Leave about 2.5 cm (1 in) of the
sensor exposed below the collar. See FIGURE
3.
Hold the collar and sensor, and finish threading the collar into the shield
by hand. Tighten the collar around the probe until it firmly grips the body
of the probe. Use an adjustable wrench if necessary, but do not overtighten
the collar.
7.3.2 Installation in a RAD10 10-Plate Shield
1.
Loosen the nut on the entry gland at the bottom of the shield.
2.
Insert the sensor up into the gland. Leave about 2.5 cm (1 in) of the sensor
exposed below the nut. See FIGURE
3.
Using an adjustable wrench, tighten the nut on the gland until the sensor is
held firmly in place. Do not overtighten.
7.3.3 Mount the Shield
1.
Attach the radiation shield to the tripod mast, crossarm, or tower leg using
the supplied U-bolt. See FIGURE
and FIGURE
shield mounting.
2.
Route the cable to the datalogger, and secure the cable to the mounting
structure using cable ties.