5.  Attach the four conductor wires from the Base Station to the to the four position 12VDC 

barrier terminal on the SPI. (See Figure 3) 

  Terminal 1: S1 DW   

  Terminal 2: S2 W      

  Terminal 3: Neutral   

  Terminal 4: 12VDC    

6.  Attach the three 120 VAC #16 AWG wires from the SPI to the three position barrier 

terminal for the pedestrian signal head visual display (See fig.1).   

7.   

a.  Orange to Don’t Walk 

b.  White to Neutral 

c.  Blue to Walk 

Warning – Danger! All SPI leads become hot when the Orange or Blue 120 VAC is connected. 

Disconnect the power to the Pedestrian Signal Head prior to SPI installation 

 

Figure 3 

 

12 VDC Outputs 

Terminal 1: S1 DW  

Terminal 2: S2 W  

Terminal 3: Neutral  

Terminal 4: 12VDC 

 

 

120 VAC INPUTS 

  Orange to Don’t Walk 

  White to Neutral 

  Blue to Walk 

 

 

 

 

 

AGPS Connections 

 

FT: Pedestrian Field Wires 

FT: Pedestrian Field Wires 

Terminal 4: 12VDC 

Terminal 3: Neutral (GND) 

Terminal 2: S2 W 

Terminal 1: S1 DW 

Orientation: 

  bottom  

 

Summary of Contents for Guardian 400A

Page 1: ...nstallation Manual 906 0003 Revision D January 20 2014 This Installation Guide provides guidance to those involved in the installation of the application This guide assumes that you have some knowledge of the operating system and the system ...

Page 2: ...ronic mechanical photocopying recording or otherwise without prior written permission from Campbell Company All copyright confidential information patents design rights and all other intellectual property rights of whatsoever nature contained herein are and shall remain the sole and exclusive property of Campbell Company The information furnished herein is believed to be accurate and reliable Howe...

Page 3: ...All rights reserved Page 3 of 15 Installation Guide 906 0003 Document Revision History Revision Revision Update Revised By Date A Released tbrennan 6 18 2012 B Released tbrennan 10 01 2012 C CAL TRANs Released ptate 10 17 2012 C1 Released Zsapp 12 21 2012 C2 Released tbrennan 12 02 213 D Released tbrennan 1 13 20013 AGPS Base Station 400A Base Station ...

Page 4: ...T 5 1 2 IDENTIFICATION 5 1 3 REFERENCE INFORMATION 5 1 4 POINTS OF CONTACT 5 2 Installation Plan 6 2 1 SCOPE 6 2 2 STANDARD COMPONENTS 6 2 3 TASKS 7 2 4 INSTALL UTILITY APPLICATION 7 2 5 INSTALLATION PROCEDURE 8 3 Post Installation 13 3 1 OPERATIONAL CHECK 13 3 2 OPERATIONAL CHECK LIST 13 4 System Requirements 14 4 1 SOFTWARE REQUIREMENTS 14 4 2 HARDWARE REQUIREMENTS 14 4 3 OPERATING SYSTEMS 14 5 ...

Page 5: ...ation Advisor Guide Pedestrian System AGPS Base Station Fully Integrated Pedestrian Station FIPS Signal Power Interface SPI Utility Version 1 3 X Firmware Version 1 3 X 1 3 Reference information See AGPS Owner s Manual for operational information See AGPS Troubleshooting Manual Reference Campbell Company Intersection Worksheet for location information 1 4 Points of Contact Customer Support Queries...

Page 6: ...n packet Pedestrian Stations are identified with the Campbell Company Work Order number and Station Identification number 2 3 Standard Components 1ea Base Station with four conductor cable 1ea Signal Power Interface 1ea USB type B cable per installation 1ea Adapter Plate see dimension Hardware options below 1ea Sign 5x7 Adapter Plate Sign Hardware and BS Mounting Hardware o 2ea 8 32 X 1 FHP Screws...

Page 7: ...t Base Station 6 Install SPI in Pedestrian Signal Head 7 Make Connections for the SPI 8 Test and Adjust 9 Fax checklist to Campbell Company 2 5 Install Utility Application The AGPS Utility application provided by Campbell Company is required before installation USB Configuration Utility Install the computer based configuration utility onto a portable computer An electronic copy of the utility is a...

Page 8: ...Company Technical Support if a security bit is needed for tactile arrow modification Note THE PEDESTRIAN RELIES ON THIS INFORMATION TO CROSS SAFELY Rubber mounting bumpers screw on to the back plate of the Base Station These are adjustable allowing for a number of configurations to ensure a precision fit especially on decorative small diameter poles where the station needs to be angled to provide ...

Page 9: ...tion See Table 1 page 10 4 Place a small bead of silicone around the flange for the back plate and tighten screws 5 Use an anti seize compound on all screws 6 Place the pedestrian station on the pole and fasten using two 20 FHP screws Ensure a snug fit 7 Place the adapter plate and or sign using provided hardware 8 Base Station Hardware kits 5x7 Adapter Plate Sign Hardware and Base Staion Mounting...

Page 10: ...e left or right requiring two security screws and a security driver Campbell Company provides this hardware packet only when specified at the time of purchase Contact Campbell Company Technical Support if a security bit is needed for tactile arrow modification Note THE PEDESTRIAN RELIES ON THIS INFORMATION TO CROSS SAFELY Install Signal Power Interface Board SPI 1 Disconnect the power to the Pedes...

Page 11: ... 120 VAC wires sag below the housing and attach to the three position barrier terminal tighten firmly securing the SPI to the back of the housing See Table 2 Note The sag in the 120 VAC wire creates a drip loop for water to drain off the SPI housing on to the bottom of the Pedestrian Signal Head Attention Do not set the SPI on the bottom of the Pedestrian Signal Head Failure to attach the SPI vert...

Page 12: ...I to the three position barrier terminal for the pedestrian signal head visual display See fig 1 7 a Orange to Don t Walk b White to Neutral c Blue to Walk Warning Danger All SPI leads become hot when the Orange or Blue 120 VAC is connected Disconnect the power to the Pedestrian Signal Head prior to SPI installation Figure 3 12 VDC Outputs Terminal 1 S1 DW Terminal 2 S2 W Terminal 3 Neutral Termin...

Page 13: ...Walk Phase message verify an audible locator tone is present at the clearance phase Flashing Don t Walk 6 Recheck all units for a full cycle to ensure all options and features operate as desired 7 Depending on intersection location factory default settings for volume AGC and vibro tactile settings may require modifications Proceed to the System Configuration section for details 3 2 Operational Che...

Page 14: ...ll this application USB Configuration Utility A computer based USB configuration utility down load onto a portable computer A USB connection is required for base station communications 4 2 Hardware Requirements The recommended minimum specifications for the computer include the following Computer USB port USB cable type B 4 3 Operating Systems The Utility operates on the following operating system...

Page 15: ...rom 1 3 seconds may activate special features including audible beaconing and extended pedestrian clearance interval EP Intersection Worksheet Intersection Map of street names and station locations provided with installation packet Pedestrian Stations are identified with Campbell Company Work order and Station Identification number Signal Power Interface SPI Power Source that interfaces with Pedes...

Reviews: