CSAT3B Three-Dimensional Sonic Anemometer
44
FIGURE 7-16. RS-485 cable connections
7.7.4 USB
If data collection from the anemometer is to be done by a computer using USB
communications, first connect to the CSAT3B as described in Section
(p. 23)
,
to confirm the following three settings:
Operating Mode:
•
Mode 2: Self triggered | No filter | Unprompted output to
computer
or
•
Mode 3: Self triggered | Filtered | Unprompted output to computer
(If Mode 3, select filter bandwidth.)
Unprompted Output Port:
USB Port
Unprompted Output Rate:
10, 20, 50 or 100 Hz
In
Device Configuration Utility,
the settings for
Unprompted
Output Port
and
Unprompted Output Rate
will be grayed-out
until the operating mode has been set to Mode 2 or Mode 3.
To complete installation, connect a CSAT3BCBL2 to the
Power/SDM
port by
screwing in the M16 connector into the port until tight.
A CSAT3BCBL1 may also be used for power, but the SDM wires
will not be used. The CSAT3BCSBL1 also has lighter gauge
power wires, which increases voltage losses over long cable
length, so it should only be used for shorter cable lengths.
NOTE
NOTE
CSAT3BCBL2-L-PT
CSAT3BCBL3-L-RJ
Grounding Cable