CSAT3B Three-Dimensional Sonic Anemometer
26
TABLE 7-1. CSAT3B Settings and Status Values in
Device Configuration Utility
Subscreen
Setting or Status
Value
Options
Description
Measurement
Settings
Operating Mode
Mode 0
: Data logger
triggered | No filter |
Data logger
prompted output
1/
Mode 1
: Self
triggered | Filtered |
Data logger
prompted output
Mode 2
: Self
triggered | No filter |
Unprompted output
to computer
Mode 3
: Self
triggered | Filtered |
Unprompted output
to computer
Identifies the source of the measurement
trigger, whether a low pass filter will be
applied, and the output mode (see Section
(p. 48)
, for more details on
operating mode)
Filter Bandwidth
5 Hz
10 Hz
20 Hz
25 Hz
The cut-off frequency of the low pass filter.
Only applicable if in Operating Mode 1 or 3.
Sonic Transducer
Shadow
Correction
Disabled
Enabled
Applies an optional Kaimal correction for
wind shadowing of the sonic transducers. See
(p. 47)
Instrument ID
Anemometer
Serial Number
Serial Number
1/
The serial number of the CSAT3B
User ID String
Blank
1/
A unique identifier in addition to the serial
number that the user may assign
Factory ID String
Blank
1/
A unique identifier in addition to the serial
number that the factory may assign
OS Version
-
The version number of the CSAT3B operating
system
OS Date
-
The date the loaded operating system was built
1/
Denotes a factory default setting
Factory defaults for all setting may be restored by clicking the
Factory Defaults
button at the bottom of the screen in the
Device
Configuration Utility
.
The SDM communications port is always enabled.
NOTE
NOTE