CSAT3B Three-Dimensional Sonic Anemometer
17
) should be ordered to
connect the HUB-SDM8 to a data logger and a power supply.
FIGURE 5-12. HUB-SDM8 for multiple CSAT3B connections with SDM
communications
5.2.4.4 SDM Cable CABLE5CBL-L
The SDM cable, CABLE5CBL-L, is a 22 AWG, five-conductor cable with a
Santoprene jacket and an aluminum Mylar shield. By default, the conductors
are stripped and tinned.
The CABLE5CBL-L is used to connect the power and SDM connection from a
HUB-SDM8 to the power and SDM connections on a power source and data
logger.
5.2.4.5 HUB-CPI
The 8-channel RJ45 HUB-CPI allows up to eight CPI devices to be connected
together in parallel. In the case of the CSAT3B, up to seven CSAT3Bs, or
CSAT3B daisy-chains using CSAT3BCBL3 cables, may be connected in
parallel to the HUB-CPI. The remaining port may be used with a CAT5e or
CAT6 Ethernet cable (see Section
(p. 17)
) to
connect the HUB-CPI to the CPI port on a data logger such as the CR6.
The HUB-CPI (shown in FIGURE
) is not weatherproof and should be
housed in an enclosure, typically alongside the data logger.