information.
9.1 Maintenance
The CS240 and CS240DM sensors require minimal maintenance. Periodically check cabling for
proper connections, signs of damage, and possible moisture intrusion.
9.2 Troubleshooting
Symptom: Temperature is NAN, –INF, –9999, –273
Verify wiring of sensor to the data logger; cross-reference data logger program or the
measurement system wiring diagram.
Symptom: Incorrect Temperature
Check the cable for signs of damage and possible moisture intrusion.
Symptom: Unstable Temperature
Make sure the clear shield or white/green striped wire is connected to data logger ground,
and the data logger is properly grounded. For the CS240, try using the 60 or 50 Hz
integration options and/or increasing the settling time.
CS240 and CS240DM PT-1000 Class A, Back-of-Module Temperature Sensors