Appendix A. Info Tables and Settings
550
Reports how many records have been skipped in a data table. Array elements are in the
order that data tables are declared in the CRBasic program. Enter
0
to reset.
SkippedScan
Numeric Y
•
Station Status field:
Skipped Scans
•
Status
table field: ≈22
Number of
skipped program scans
(p. 472)
that have occurred while running the CRBasic
program. Does not include scans intentionally skipped as may occur with the use of
ExitScan
and
Do
/
Loop
instructions. Updated when they occur.
SkippedSlow
Scan()
Numeric Y
•
Station Status field:
Skipped Slow Scans
•
Status
table field: ≈24
Number of skipped scans for each
SlowSequence
scan in the CRBasic program. See
LastSlowScan
(p. 543),
MaxSlowProcTime
(p. 544),
SlowProcTime
(p. 550).
Skipped
SystemScan()
Numeric Y
•
Station Status field:
Skipped System Scans
•
Status
table field: ≈23
Number of scans skipped in the auto (background) calibration. Enter 0 to reset. See
LastSystemScan
(p. 543),
MaxSystemProcTime
(p. 544),
and
SystemProcTime
(p. 550).
SlowProcTime()
Numeric Y
•
Status
table field: ≈39
Time (μs) required to process a
SlowSequence
scan. See
LastSlowScan
(p. 543),
MaxSlowProcTime
(p. 544),
SkippedSlowScan
(p. 550).
Default is a large number until a
SlowSequence
runs.
StartTime
NSEC
Y
•
Station Status field:
Start Time
•
Status
table field: 8
Time (date and time) the CRBasic program started. Updates at beginning of program
compile.
StartUpCode
Numeric Y
•
Status
table field: ≈19
Indicates how the running program was compiled.
True
: program compiled by CR800
starting from a power-down condition.
False
: program compiled by either a
Program
Send
, a
File Control
transaction, or a watchdog reset. Updated at startup.
StationName
String
•
Station Status field:
Reported Station Name
•
Settings Editor:
Datalogger | Station Name
•
Status
table field: 6
Station name stored in flash memory. This is not the same name as that is entered into
LoggerNet
. This station name can be sampled into a data table, but it is not the name that
appears in data file headers. Updated at startup or when the name is changed.
SW12Volts()
Numeric
•
Status
table field: ≈44
Status of switched, 12 Vdc terminal.
True
= on. Updates when the state changes.
Summary of Contents for CR800 Series
Page 2: ......
Page 4: ......
Page 6: ......
Page 32: ......
Page 34: ......
Page 54: ......
Page 92: ......
Page 310: ......
Page 446: ...Section 8 Operation 446 8 11 2 Data Display FIGURE 100 CR1000KD Displaying Data ...
Page 448: ...Section 8 Operation 448 FIGURE 102 CR1000KD Real Time Custom ...
Page 449: ...Section 8 Operation 449 8 11 2 3 Final Storage Data FIGURE 103 CR1000KD Final Storage Data ...
Page 450: ...Section 8 Operation 450 8 11 3 Run Stop Program FIGURE 104 CR1000KD Run Stop Program ...
Page 452: ...Section 8 Operation 452 FIGURE 106 CR1000KD File Edit ...
Page 456: ......
Page 462: ......
Page 523: ...Section 11 Glossary 523 FIGURE 116 Relationships of Accuracy Precision and Resolution ...
Page 524: ......
Page 526: ......
Page 556: ......
Page 558: ......
Page 560: ......
Page 597: ......