Section 7. Installation
212
7.7.9.1 OutputOpt Parameters
In the CR3000 WindVector() instruction, the OutputOpt parameter defines the
processed data that are stored. All output options result in an array of values, the
elements of which have _WVc(n) as a suffix, where n is the element number. The
array uses the name of the Speed/East variable as its base. See table
WindVector() OutputOpt Options
(p. 212).
WindVector() OutputOpt Options
Option
Description (WVc() is the Output Array)
0
WVc(1): Mean horizontal wind speed (S)
WVc(2): Unit vector mean wind direction (Θ1)
WVc(3): Standard deviation of wind direction
σ
(Θ1). Standard
deviation is calculated using the Yamartino algorithm. This
option complies with EPA guidelines for use with straight-line
Gaussian dispersion models to model plume transport.
1
WVc(1): Mean horizontal wind speed (S)
WVc(2): Unit vector mean wind direction (Θ1)
2
WVc(1): Mean horizontal wind speed (S)
WVc(2): Resultant mean horizontal wind speed (U)
WVc(3): Resultant mean wind direction (Θu)
WVc(4): Standard deviation of wind direction σ(Θu). This
standard deviation is calculated using Campbell Scientific's wind
speed weighted algorithm. Use of the resultant mean horizontal
wind direction is not recommended for straight-line Gaussian
dispersion models, but may be used to model transport direction
in a variable-trajectory model.
3
WVc(1): Unit vector mean wind direction (Θ1)
4
WVc(1): Unit vector mean wind direction (Θ1)
WVc(2):
Standard deviation of wind direction σ(Θu). This
standard deviation is calculated using Campbell Scientific's wind
speed weighted algorithm. Use of the resultant mean horizontal
wind direction is not recommended for straight-line Gaussian
dispersion models, but may be used to model transport direction
in a variable-trajectory model.
7.7.9.2 Wind Vector Processing
WindVector() uses a zero-wind-speed measurement when processing scalar wind
speed only. Because vectors require magnitude and direction, measurements at
zero wind speed are not used in vector speed or direction calculations. This
means, for example, that manually-computed hourly vector directions from 15
minute vector directions will not agree with CR3000-computed hourly vector
directions. Correct manual calculation of hourly vector direction from 15 minute
vector directions requires proper weighting of the 15 minute vector directions by
the number of valid (non-zero wind speed) wind direction samples.
Summary of Contents for CR3000 Micrologger
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ......
Page 30: ......
Page 34: ......
Page 36: ......
Page 96: ......
Page 485: ...Section 8 Operation 485 8 11 2 Data Display FIGURE 110 Keyboard and Display Displaying Data ...
Page 487: ...Section 8 Operation 487 FIGURE 112 CR1000KD Real Time Custom ...
Page 491: ...Section 8 Operation 491 FIGURE 116 Keyboard and Display File Edit ...
Page 496: ......
Page 502: ......
Page 564: ...Section 11 Glossary 564 FIGURE 126 Relationships of Accuracy Precision and Resolution ...
Page 566: ......
Page 594: ......
Page 598: ......
Page 600: ......
Page 602: ......
Page 624: ......
Page 642: ......
Page 643: ......